Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractAtWRKY22 promotes susceptibility to aphids and modulates salicylic acid and jasmonic acid signalling    Next AbstractAccidental exposure to gas emissions from transit goods treated for pest control »

Rapid Commun Mass Spectrom


Title:Implementation of an enclosed ionization interface for the analysis of liquid sample streams with direct analysis in real time mass spectrometry
Author(s):Kloth R; Khanipour P; Mayrhofer KJJ; Katsounaros I;
Address:"Helmholtz Institute Erlangen-Nurnberg for Renewable Energy (IEK-11), Forschungszentrum Julich GmbH, Egerlandstr. 3, Erlangen, 91058, Germany. Department of Chemical and Biological Engineering, Friedrich-Alexander University Erlangen-Nurnberg, Egerlandstr. 3, Erlangen, 91058, Germany"
Journal Title:Rapid Commun Mass Spectrom
Year:2021
Volume:35
Issue:13
Page Number:e9091 -
DOI: 10.1002/rcm.9091
ISSN/ISBN:1097-0231 (Electronic) 0951-4198 (Linking)
Abstract:"RATIONALE: The development of an interface to analyze liquid sample streams with direct analysis in real time mass spectrometry (DART-MS) is of great interest for coupling various analytical techniques, using non-volatile salts, with MS. Therefore, we devised an enclosed ionization interface and a sample introduction system for the versatile analysis of liquid samples with DART-MS. METHODS: The sample introduction system consists of a nebulizer, a spray chamber and a transfer line, while the confined ionization interface is created by implementing a cross-shaped housing between ion source outlet and mass spectrometer inlet. Methodical studies of the effects of various setup parameters on signal intensity and peak shape were conducted, while its diverse applicability was demonstrated by coupling with high-performance liquid chromatography (HPLC) for the analysis of alcohols, organic acids and furanic compounds. RESULTS: The confinement of the ionization interface results in a robust setup design with a well-defined ionization region for focusing of the sprayed sample mist. Thereby, an increase in analyte signal intensity by three orders of magnitude and improved signal stability and reproducibility were obtained in comparison with a similar open ionization interface configuration. Additionally, the successful quantification of alcohols could be demonstrated as well as the compatibility of the setup with HPLC gradient elution. CONCLUSIONS: A versatile setup design for the analysis of liquid sample streams with DART-MS was devised for monitoring reactions or hyphenating analytics with MS. The design minimizes interferences from the laboratory surroundings as well as allows for safe handling of hazardous and toxic chemicals, which renders it suitable for a broad range of applications"
Keywords:
Notes:"PubMed-not-MEDLINEKloth, Ricarda Khanipour, Peyman Mayrhofer, Karl J J Katsounaros, Ioannis eng Research Foundation/ 390919832/Deutsche Forschungsgemeinschaft/ England 2021/04/01 Rapid Commun Mass Spectrom. 2021 Jul 15; 35(13):e9091. doi: 10.1002/rcm.9091"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024