Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractLack of effect of vaginal lavages and aliphatic acids on ejaculatory responses in rhesus monkeys: behavioral and chemical analyses    Next AbstractDevelopmental changes in pre-adult behavior in confined colonies of golden hamsters »

J Immigr Minor Health


Title:Indoor air quality survey of nail salons in Boston
Author(s):Goldin LJ; Ansher L; Berlin A; Cheng J; Kanopkin D; Khazan A; Kisivuli M; Lortie M; Bunker Peterson E; Pohl L; Porter S; Zeng V; Skogstrom T; Fragala MA; Myatt TA; Stewart JH; Allen JG;
Address:"Environmental Studies, Brandeis University, 415 South Street, MS055, Waltham, MA, 02453, USA, goldin@brandeis.edu"
Journal Title:J Immigr Minor Health
Year:2014
Volume:16
Issue:3
Page Number:508 - 514
DOI: 10.1007/s10903-013-9856-y
ISSN/ISBN:1557-1920 (Electronic) 1557-1912 (Print) 1557-1912 (Linking)
Abstract:"Employees in nail salons, largely Vietnamese immigrant women in Boston, are exposed to a range of volatile organic chemicals from the products used in salons, including solvents, glues and polishes. Some of these chemicals have the potential to cause short and long-term adverse health effects. Only limited research has been performed on assessing occupational exposures. This project aimed to characterize total volatile organic compound (TVOC) and PM2.5 concentrations in nail salons as a function of ventilation, building characteristics, customer and employee occupancy, and type of services being performed. Students conducted sampling in 21 salons in Boston, MA from September to December, 2011. Study visits included: indoor environmental quality measurements (TVOCs, PM2.5 and carbon dioxide), site observations, and an interview. CO2 levels in 15 of 21 salons exceeded 800 ppm, suggesting that these salons may have insufficient ventilation. Higher TVOC and PM2.5 levels were found in salons with less ventilation (as estimated using CO2 concentrations). Contrary to our a priori hypothesis, average levels of TVOCs, CO2 and PM2.5 were consistent throughout salons, indicating that exposures may not be restricted to areas in the salon where work is being performed (e.g., at the manicure table). Higher TVOC concentrations were observed when tasks were being performed, yet were not dependent upon the number of tasks being performed. Improving ventilation conditions in salons to meet minimum outdoor air delivery requirements can reduce exposures to TVOCs"
Keywords:"Adult Air Pollution, Indoor/*statistics & numerical data Asian/statistics & numerical data *Beauty Culture Boston Cross-Sectional Studies Environmental Monitoring/methods/*statistics & numerical data Female Humans Incidence Middle Aged Nails Occupational;"
Notes:"MedlineGoldin, Laura J Ansher, Liza Berlin, Ariana Cheng, Jenny Kanopkin, Deena Khazan, Anna Kisivuli, Meda Lortie, Molly Bunker Peterson, Emily Pohl, Laura Porter, Sam Zeng, Vivian Skogstrom, Tiffany Fragala, Matt A Myatt, Theodore A Stewart, James H Allen, Joseph G eng 2013/06/15 J Immigr Minor Health. 2014 Jun; 16(3):508-14. doi: 10.1007/s10903-013-9856-y"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 26-06-2024