Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractImproved processing of secretory proteins in Hansenula polymorpha by sequence variation near the processing site of the alpha mating factor prepro sequence    Next AbstractBreath analysis of cancer in the present and the future »

ACS Nano


Title:Detection of Single Cancer Cells in Blood with Artificially Intelligent Nanoarray
Author(s):Einoch-Amor R; Broza YY; Haick H;
Address:"Department of Chemical Engineering and Russell Berrie Nanotechnology Institute, Technion-Israel Institute of Technology, 3200003, Haifa, Israel"
Journal Title:ACS Nano
Year:2021
Volume:20210331
Issue:4
Page Number:7744 - 7755
DOI: 10.1021/acsnano.1c01741
ISSN/ISBN:1936-086X (Electronic) 1936-0851 (Linking)
Abstract:"Detection and monitoring of single cancer cells (SCCs), such as circulating tumor cells (CTCs), would be of aid in an efficient early detection of cancer, a tailored (personalized) therapy, and in a fast bedside assessment of treatment efficacy. Nevertheless, currently available techniques, which mostly rely on the isolation of SCCs based on their physical or biological properties, suffer from low sensitivity, complicated technical procedures, low cost-effectiveness, and being unsuitable for continuous monitoring. We report here on the design and use of an artificially intelligent nanoarray based on a heterogeneous set of chemisensitive nanostructured films for the detection of SCCs using volatile organic compounds emanating in the air trapped above blood samples containing SCCs. For demonstration purposes, we have focused on samples containing A549 lung cancer cells (hereafter, SCC(A549)). The nanoarray developed to detect SCC(A549) has >90% accuracy, >85% sensitivity, and >95% specificity. Detection works irrespective of the medium and/or the environment. These results were validated by complementary mass spectrometry. The ability to continuously record, store, and preprocess the signals increases the chances that this nanotechnology might also be useful in the early detection of cancer cells in the blood and continuous monitoring of their possible progression"
Keywords:"A549 Cells Humans *Lung Neoplasms *Nanostructures Nanotechnology *Neoplastic Cells, Circulating Ctc blood cancer diagnosis sensor volatile organic compound;"
Notes:"MedlineEinoch-Amor, Reef Broza, Yoav Y Haick, Hossam eng 2021/04/01 ACS Nano. 2021 Apr 27; 15(4):7744-7755. doi: 10.1021/acsnano.1c01741. Epub 2021 Mar 31"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 23-11-2024