Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractThe herbicide atrazine induces hyperactivity and compromises tadpole detection of predator chemical cues    Next AbstractLimits of separation of a multi-capillary column with mixtures of volatile organic compounds for a flame ionization detector and a differential mobility detector »

J Chromatogr A


Title:"Miniature radio-frequency mobility analyzer as a gas chromatographic detector for oxygen-containing volatile organic compounds, pheromones and other insect attractants"
Author(s):Eiceman GA; Tadjikov B; Krylov E; Nazarov EG; Miller RA; Westbrook J; Funk P;
Address:"Department of Chemistry and Biochemistry, New Mexico State University, Las Cruces 88003-0001, USA. geiceman@nmsu.edu"
Journal Title:J Chromatogr A
Year:2001
Volume:917
Issue:1-Feb
Page Number:205 - 217
DOI: 10.1016/s0021-9673(01)00656-2
ISSN/ISBN:0021-9673 (Print) 0021-9673 (Linking)
Abstract:"A high electric field, radio-frequency ion mobility spectrometry (RF-IMS) analyzer was used as a small detector in gas chromatographic separations of mixtures of volatile organic compounds including alcohols, aldehydes, esters, ethers, pheromones, and other chemical attractants for insects. The detector was equipped with a 2 mCi 63Ni ion source and the drift region for ion characterization was 5 mm wide, 15 mm long and 0.5 mm high. The rate of scanning for the compensation voltages was 60 V s(-1) and permitted four to six scans to be obtained across a capillary chromatographic elution profile for each component. The RF-IMS scans were characteristic of a compound and provided a second dimension of chemical identity to chromatographic retention adding specificity in instances of co-elution. Limits of detection were 1.6-55 x 10(-11) g with an average detection limit for all chemicals of 9.4 x 10(-11) g. Response to mass was linear from 2-50 x 10(-10) g with an average sensitivity of 4 pA ng(-1). Separations of pheromones and chemical attractants for insects illustrated the distinct patterns obtained from gas chromatography with RF-IMS scans in real time and suggest an analytical utility of the RF-IMS as a small, advanced detector for on-site gas chromatographs"
Keywords:"Chromatography, Gas/*instrumentation Organic Chemicals/*analysis Oxygen/*analysis Pheromones/*analysis Radio Waves Sensitivity and Specificity Volatilization;"
Notes:"MedlineEiceman, G A Tadjikov, B Krylov, E Nazarov, E G Miller, R A Westbrook, J Funk, P eng Research Support, Non-U.S. Gov't Netherlands 2001/06/14 J Chromatogr A. 2001 May 11; 917(1-2):205-17. doi: 10.1016/s0021-9673(01)00656-2"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 19-12-2024