Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractChemical cues for sea lamprey migration    Next AbstractIsolation and functional characterization of novel isoprene synthase from Artocarpus heterophyllus (jackfruit) »

Environ Sci Process Impacts


Title:Indoor and outdoor air quality impacts of cooking and cleaning emissions from a commercial kitchen
Author(s):Ditto JC; Crilley LR; Lao M; VandenBoer TC; Abbatt JPD; Chan AWH;
Address:"Department of Chemical Engineering and Applied Chemistry, University of Toronto, Toronto, Canada. arthurwh.chan@utoronto.ca. Department of Chemistry, University of Toronto, Toronto, Canada. jonathan.abbatt@utoronto.ca. Department of Chemistry, York University, Toronto, Canada"
Journal Title:Environ Sci Process Impacts
Year:2023
Volume:20230525
Issue:5
Page Number:964 - 979
DOI: 10.1039/d2em00484d
ISSN/ISBN:2050-7895 (Electronic) 2050-7887 (Linking)
Abstract:"Gas and particulate emissions from commercial kitchens are important contributors to urban air quality. Not only are these emissions important for occupational exposure of kitchen staff, but they can also be vented to outdoors, causing uncertain health and environmental impacts. In this study, we chemically speciated volatile organic compounds and measured particulate matter mass concentrations in a well-ventilated commercial kitchen for two weeks, including during typical cooking and cleaning operations. From cooking, we observed a complex mixture of volatile organic gases dominated by oxygenated compounds commonly associated with the thermal degradation of cooking oils. Gas-phase chemicals existed at concentrations 2-7 orders of magnitude lower than their exposure limits, due to the high ventilation in the room (mean air change rate of 28 h(-1) during operating hours). During evening kitchen cleaning, we observed an increase in the signal of chlorinated gases from 1.1-9.0 times their values during daytime cooking. Particulate matter mass loadings tripled at these times. While exposure to cooking emissions in this indoor environment was reduced effectively by the high ventilation rate, exposure to particulate matter and chlorinated gases was elevated during evening cleaning periods. This emphasizes the need for careful consideration of ventilation rates and methods in commercial kitchen environments during all hours of kitchen operation"
Keywords:"Humans *Air Pollution, Indoor/analysis Environmental Monitoring/methods *Air Pollution Particulate Matter/analysis Gases Cooking *Air Pollutants/analysis;"
Notes:"MedlineDitto, Jenna C Crilley, Leigh R Lao, Melodie VandenBoer, Trevor C Abbatt, Jonathan P D Chan, Arthur W H eng England 2023/04/27 Environ Sci Process Impacts. 2023 May 25; 25(5):964-979. doi: 10.1039/d2em00484d"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-11-2024