Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractComparisons of human-landing catches and odor-baited entry traps for sampling malaria vectors in Senegal    Next AbstractDeveloping a multimedia model of chemical dynamics in an urban area »

Anal Chim Acta


Title:Continuous determination of volatile products in anaerobic fermenters by on-line capillary gas chromatography
Author(s):Diamantis V; Melidis P; Aivasidis A;
Address:"Laboratory for Wastewater Management and Treatment Technologies, Department of Environmental Engineering, Democritus University of Thrace, Vas. Sofias 12, PROKAT, GR-67100 Xanthi, Greece. bdiamant@env.duth.gr"
Journal Title:Anal Chim Acta
Year:2006
Volume:20060517
Issue:
Page Number:189 - 194
DOI: 10.1016/j.aca.2006.05.036
ISSN/ISBN:1873-4324 (Electronic) 0003-2670 (Linking)
Abstract:"Bio-ethanol and biogas produced during the anaerobic conversion of organic compounds has been a subject of great interest since the oil crisis of the 1970s. In ethanol fermentation and anaerobic treatment of wastewaters, end-product (ethanol) and intermediate-products (short-chain fatty acids, SCFA) cause inhibition that results in reduced process efficiency. Control of these constituents is of utmost importance for bioreactor optimization and process stability. Ethanol and SCFA can be detected with precision by capillary gas chromatography usually conducted in off-line measurements. In this work, an on-line monitoring and controlling system was developed and connected to the fermenter via an auto-sampling equipment, which could perform the feeding, filtration and dilution of the sample and final injection into the gas chromatograph through an automation-based programmed procedure. The sample was continuously pumped from the recycle stream of the bioreactor and treated using a microfiltration unit. The concentrate was returned to the reactor while the permeate was quantitatively mixed with an internal standard solution. The system comprised of a gas chromatograph with the flow cell and one-shot sampler and a PC with the appropriate software. The on-line measurement of ethanol and SCFA, directly from the liquid phase of an ethanol fermenter and a high-rate continuous mode anaerobic digester, was accomplished by gas chromatography. Also, this monitoring and controlling system was proved to be effective in the continuous fermentation of alcohol-free beer"
Keywords:
Notes:"PubMed-not-MEDLINEDiamantis, V Melidis, P Aivasidis, A eng Netherlands 2007/08/29 Anal Chim Acta. 2006 Jul 28; 573-574:189-94. doi: 10.1016/j.aca.2006.05.036. Epub 2006 May 17"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 25-12-2024