Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractSensing Technologies for Detection of Acetone in Human Breath for Diabetes Diagnosis and Monitoring    Next AbstractPherokine-2 and -3 »

Rapid Commun Mass Spectrom


Title:A simple method for the extraction of volatile organic compounds contained in air samples from adsorbent materials by solid phase microextraction and their analysis by gas chromatography/mass spectrometry
Author(s):Saba A; Raffaelli A; Pucci S; Salvadori P;
Address:"Centro di Studio del CNR per le Macromolecole Stereordinate ed Otticamente Attive, Dipartimento di Chimica e Chimica Industriale, Universita di Pisa, Via Risorgimento 35, 56126 Pisa, Italy"
Journal Title:Rapid Commun Mass Spectrom
Year:1999
Volume:13
Issue:19
Page Number:1899 - 1902
DOI: 10.1002/(SICI)1097-0231(19991015)13:19<1899::AID-RCM721>3.0.CO;2-L
ISSN/ISBN:0951-4198 (Print) 0951-4198 (Linking)
Abstract:"The monitoring of air pollution requires simple, rapid and sensitive sampling and analytical techniques with minimal sample manipulation that are usable for routine analyses. In our laboratories we have developed a method for the analysis of air samples collected by adsorbent cartridges based on solid phase microextraction (SPME) coupled to gas chromatography/mass spectrometry. We investigated the influence of some variables (time and temperature) using toluene as analyte (one of the most common air pollutants) and toluene-d(8) on the SPME extraction, and the sensitivity (LOQ) of the method. We then tested the method on an air sample collected in an industrial area and carried out characterisation of the volatile organic compounds present"
Keywords:Adsorption Air Pollutants/*analysis Environmental Monitoring Gas Chromatography-Mass Spectrometry/*methods Industrial Waste Sensitivity and Specificity Temperature Toluene/analysis Volatilization;
Notes:"MedlineSaba, A Raffaelli, A Pucci, S Salvadori, P eng England 1999/09/17 Rapid Commun Mass Spectrom. 1999; 13(19):1899-902. doi: 10.1002/(SICI)1097-0231(19991015)13:19<1899::AID-RCM721>3.0.CO; 2-L"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 19-12-2024