Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractSeasonal volatility dependence of ambient particle phase amines    Next AbstractRegulation of Isoprenoid Pheromone Biosynthesis in Bumblebee Males »

Rapid Commun Mass Spectrom


Title:Proton transfer reaction ion trap mass spectrometer
Author(s):Prazeller P; Palmer PT; Boscaini E; Jobson T; Alexander M;
Address:"Pacific Northwest National Laboratory, 3020 Q Avenue, K8-93, Richland, WA 99352, USA"
Journal Title:Rapid Commun Mass Spectrom
Year:2003
Volume:17
Issue:14
Page Number:1593 - 1599
DOI: 10.1002/rcm.1088
ISSN/ISBN:0951-4198 (Print) 0951-4198 (Linking)
Abstract:"Proton transfer reaction mass spectrometry is a relatively new field that has attracted a great deal of interest in the last few years. This technique uses H(3)O(+) as a chemical ionization (CI) reagent to measure volatile organic compounds (VOCs) in the parts per billion by volume (ppbv) to parts per trillion by volume (pptv) range. Mass spectra acquired with a proton transfer reaction mass spectrometer (PTR-MS) are simple because proton transfer chemical ionization is 'soft' and results in little or no fragmentation. Unfortunately, peak identification can still be difficult due to isobaric interferences. A possible solution to this problem is to couple the PTR drift tube to an ion trap mass spectrometer (ITMS). The use of an ITMS is appealing because of its ability to perform MS/MS and possibly distinguish between isomers and other isobars. Additionally, the ITMS duty cycle is much higher than that of a linear quadrupole so faster data acquisition rates are possible that will allow for detection of multiple compounds. Here we present the first results from a proton transfer reaction ion trap mass spectrometer (PTR-ITMS). The aim of this study was to investigate ion injection and storage efficiency of a simple prototype instrument in order to estimate possible detection limits of a second-generation instrument. Using this prototype a detection limit of 100 ppbv was demonstrated. Modifications are suggested that will enable further reduction in detection limits to the low-ppbv to high-pptv range. Furthermore, the applicability of MS/MS in differentiating between isobaric species was determined. MS/MS spectra of the isobaric compounds methyl vinyl ketone (MVK) and methacrolein (MACR) are presented and show fragments of different mass making differentiation possible, even when a mixture of both species is present in the same sample. However, MS/MS spectra of acetone and propanal produce fragments with the same molecular masses but with different intensity ratios. This allows quantitative distinction only if one species is predominant. Fragmentation mechanisms are proposed to explain the results"
Keywords:
Notes:"PubMed-not-MEDLINEPrazeller, Peter Palmer, Peter T Boscaini, Elena Jobson, Tom Alexander, Michael eng England 2003/07/08 Rapid Commun Mass Spectrom. 2003; 17(14):1593-9. doi: 10.1002/rcm.1088"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 18-11-2024