Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractVolatile organic compounds of Thai honeys produced from several floral sources by different honey bee species    Next AbstractSingle-cell analysis reveals that insulation maintains signaling specificity between two yeast MAPK pathways with common components »

Environ Sci Process Impacts


Title:Soil gas carbon dioxide probe: laboratory testing and field evaluation
Author(s):Patterson BM; Furness AJ; Bastow TP;
Address:"CSIRO Land and Water, Private Bag 5, Wembley, WA 6913, Australia. bradley.patterson@csiro.au"
Journal Title:Environ Sci Process Impacts
Year:2013
Volume:15
Issue:5
Page Number:1062 - 1069
DOI: 10.1039/c3em00100h
ISSN/ISBN:2050-7895 (Electronic) 2050-7887 (Linking)
Abstract:"An automated semi-continuous on-line instrument has been developed to measure CO2 gas concentrations in the vadose zone. The instrument uses semi-permeable polymer tubing (CO2 probe) for diffusion based sampling, coupled to an infra red sensor. The system operated automatically by intermittently purging the CO2 probe, which was installed in the vadose zone, with a non-CO2 gas at a low flow rate. The gas exiting the CO2 probe was monitored at the ground surface using a miniature infra red sensor and the response related to the vadose zone soil gas CO2 concentration. The in situ CO2 probes provided a reliable monitoring technique under long-term (18 months) aggressive and dynamic field conditions, with no interference observed from non-CO2 gases and volatile organic compounds. The probes provided data that were comparable to conventional grab sampling techniques without the labour-intensive sample collection and processing associated with these conventional techniques. Also, disturbance to vadose zone CO2 profiles from repeated grab samples during long-term semi-continuous monitoring could potential be reduced by using the diffusion based sampling technique"
Keywords:"Calibration Carbon Dioxide/*analysis Diffusion Environmental Monitoring/*instrumentation Equipment Design Gases/*analysis Hydrocarbons, Chlorinated/analysis Soil/*analysis Soil Pollutants/analysis Temperature;"
Notes:"MedlinePatterson, B M Furness, A J Bastow, T P eng Evaluation Study Research Support, Non-U.S. Gov't England 2013/04/09 Environ Sci Process Impacts. 2013 May; 15(5):1062-9. doi: 10.1039/c3em00100h"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 19-12-2024