« Previous AbstractTetrathiafulvalene (TTF)-Annulated Calix[4]pyrroles: Chemically Switchable Systems with Encodable Allosteric Recognition and Logic Gate Functions    Next Abstract"Olfactory attraction mediated by the maxillary palps in the striped fruit fly, Bactrocera scutellata: Electrophysiological and behavioral study" »

J Environ Sci Health A Tox Hazard Subst Environ Eng


Title:"Removal of chemical hazardous compounds using CATACOAT, a nano-platinum thermal catalyst system"
Author(s):Park JS; Chang JE;
Address:"Department of Laboratory Medicine, Seoul National University Bundang Hospital, Seongnam-Si, Republic of Korea. College of Pharmacy, Dongduk Women's University, Seoul, Republic of Korea"
Journal Title:J Environ Sci Health A Tox Hazard Subst Environ Eng
Year:2021
Volume:20211123
Issue:14
Page Number:1471 - 1479
DOI: 10.1080/10934529.2021.2007008
ISSN/ISBN:1532-4117 (Electronic) 1093-4529 (Linking)
Abstract:"The performance of CATACOAT, a nano-platinum thermal catalyst system, was evaluated for the removal of chemical hazardous compounds from air. Xylene, benzene, styrene, and toluene were selected as standard volatile organic compounds (VOCs) in this study. In addition, formaldehyde was tested as a chemical hazardous compound. Each VOC, or formaldehyde, was evaporated in a 4,000 L chamber under controlled environments. At the maximum concentration point, CATACOAT was turned on and the concentrations of the chemical hazardous compounds were recorded for 5 h. The air purifier based on H-13-grade high-efficiency particulate air (HEPA) filter was tested in the same way to compare the effects of CATACOAT. Compared with the HEPA filter system, every VOC concentration was significantly decreased with the CATACOAT system only 0.025 h after turning on the air purifier (P values for xylene, benzene, styrene, and toluene are 0.00488, 0.01508, 0.00014, and 0.04690, respectively). After running the air cleaners for 5 h, every VOC and formaldehyde demonstrated significantly decreased concentrations with the CATACOAT system, compared with HEPA filter system (P values for xylene, benzene, styrene, toluene, and formaldehyde are 0.00034, 0.00009, 0.00008, 0.00001, and 0.00571, respectively). In conclusion, the CATACOAT may be a viable solution to control indoor air pollution"
Keywords:"*Air Pollutants/analysis *Air Pollution, Indoor/analysis Benzene/analysis Formaldehyde/analysis Platinum *Volatile Organic Compounds/analysis Volatile organic compound air purifier formaldehyde indoor air pollution novel electrochemical metal surface trea;"
Notes:"MedlinePark, Jeong Su Chang, Ji-Eun eng England 2021/11/24 J Environ Sci Health A Tox Hazard Subst Environ Eng. 2021; 56(14):1471-1479. doi: 10.1080/10934529.2021.2007008. Epub 2021 Nov 23"

 