Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractLaboratory scale evaluation of volatile organic compound emissions as indication of swine carcass degradation inside biosecure composting units    Next Abstract"Health risk assessment of occupational exposure to hazardous volatile organic compounds in swine gestation, farrowing and nursery barns" »

Bioresour Technol


Title:Air sampling methods for VOCs related to field-scale biosecure swine mortality composting
Author(s):Akdeniz N; Koziel JA; Glanville TD; Ahn H; Crawford BP;
Address:"Department of Agricultural and Biosystems Engineering, Iowa State University, Ames, IA 50011, USA"
Journal Title:Bioresour Technol
Year:2011
Volume:20101025
Issue:3
Page Number:3599 - 3602
DOI: 10.1016/j.biortech.2010.10.100
ISSN/ISBN:1873-2976 (Electronic) 0960-8524 (Linking)
Abstract:"Monitoring specific volatile organic compounds (VOCs) as markers of biosecure carcass degradation is a promising method to test progress and completion of the composting process. The objective of this study was to test the feasibility of using existing aeration ducts in composting units as practical sampling locations. The secondary objective was to test the feasibility of using marker VOC concentrations in aeration ducts to elucidate information about airflow patterns inside composting units. Marker VOC concentrations were significantly higher in the upper aeration duct and this duct can typically be used to collect air samples instead of placing special air sampling probes inside the composting units. Occasionally, the airflow direction inside composting units can change. Marker VOC concentrations can be used to decide the airflow direction inside the composting units. In this study, higher VOC concentrations were measured from the upper aeration duct, and this duct was shown to be an outlet"
Keywords:Animals Environmental Monitoring/*instrumentation Equipment Design Equipment Failure Analysis *Postmortem Changes Soil/*analysis/*chemistry *Swine Volatile Organic Compounds/*analysis;
Notes:"MedlineAkdeniz, Neslihan Koziel, Jacek A Glanville, Thomas D Ahn, Heekwon Crawford, Benjamin P eng Research Support, Non-U.S. Gov't England 2010/11/19 Bioresour Technol. 2011 Feb; 102(3):3599-602. doi: 10.1016/j.biortech.2010.10.100. Epub 2010 Oct 25"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024