« Previous AbstractPrenatal exposure to di-(2-ethylhexyl) phthalate and high-fat diet synergistically disrupts mouse fetal oogenesis and affects folliculogenesisdagger    Next AbstractOverwintering survival and spring emergence of Helicoverpa armigera (Lepidoptera: Noctuidae) in northern Greece »

J Environ Sci Health A Tox Hazard Subst Environ Eng


Title:"Selective determination of ethyl acetate, acetone, ethanol, and methyl ethyl ketone using quartz crystal nanobalance combined with principle component analysis"
Author(s):Mirmohseni A; Razzaghi MA; Pourata R; Rastgouye-Hojagan M; Zavareh S;
Address:"Polymer Technology Research Laboratory, Department of Applied Chemistry, Faculty of Chemistry, University of Tabriz, Tabriz, Iran. mirmohseni@tabrizu.ac.ir"
Journal Title:J Environ Sci Health A Tox Hazard Subst Environ Eng
Year:2009
Volume:44
Issue:9
Page Number:847 - 853
DOI: 10.1080/10934520902958492
ISSN/ISBN:1093-4529 (Print) 1093-4529 (Linking)
Abstract:"Quartz crystal nanobalance (QCN) sensors are considered as powerful mass sensitive sensors to determine materials in the subnanogram level. In the current study a method based on QCN modified with polyethylene glycol (PEG) has been developed to determine organic vapors (ethyl acetate, acetone, ethanol and methyl ethyl ketone). The frequency shift of QCN was found to be linear against analytes concentrations in the range between 4 to 35 mg/L for acetone vapor and 4-70 mg/L for 3 other vapors. The correlation coefficients for ethyl acetate, acetone, ethanol, and methyl ethyl ketone were 0.9971, 0.9976, 0.9984 and 0.9927, respectively. The principal component analysis was also utilized to process the frequency response data of the organic vapors. Using principal component analysis, it was found that over 95% of the data variance could still be explained by use of two principal components (PC1 and PC2). Subsequently, the successful discrimination of ethyl acetate and other compounds was possible through the principal component analysis of the transient responses of the PEG-modified QCN sensor"
Keywords:Acetates/*analysis Acetone/*analysis Air Pollutants/*analysis Butanones/*analysis Environmental Monitoring/instrumentation/methods Ethanol/*analysis Nanoparticles/*chemistry Polyethylene Glycols/chemistry Principal Component Analysis Quartz/*chemistry Vol;
Notes:"MedlineMirmohseni, A Razzaghi, M A Pourata, R Rastgouye-Hojagan, M Zavareh, S eng Research Support, Non-U.S. Gov't England 2009/10/06 J Environ Sci Health A Tox Hazard Subst Environ Eng. 2009 Jul 15; 44(9):847-53. doi: 10.1080/10934520902958492"

 