Title: | Two-dimensional on-line detection of brominated and iodinated volatile organic compounds by ECD and ICP-MS after GC separation |
Address: | "Institute of Inorganic Chemistry and Analytical Chemistry, Johannes Gutenberg-University, Duesbergweg 10-14, 55099 Mainz, Germany" |
DOI: | 10.1007/s00216-002-1422-8 |
ISSN/ISBN: | 1618-2642 (Print) 1618-2642 (Linking) |
Abstract: | "Inductively coupled plasma-mass spectrometry (ICP-MS) was coupled to a gas chromatographic (GC) system with electron capture detector (ECD), which enables relatively easy characterization and quantification of brominated and iodinated (halogenated) volatile organic compounds (HVOCs) in aquatic and air samples. The GC-ECD system is connected in series with an ICP-MS by a directly heated transfer line and an outlet port-hole for elimination of the ECD make-up gas during ignition of the plasma. The hyphenated GC-ECD/ICP-MS system provides high selectivity and sensitivity for monitoring individual HVOCs under fast chromatographic conditions. The ECD is most sensitive for the detection of chlorinated and brominated but the ICP-MS for iodinated compounds. The greatest advantage of the use of an ICP-MS is its element-specific detection, which allows clear identification of compounds in most cases. The absolute detection limits for ICP-MS are 0.5 pg for iodinated, 10 pg for brominated, and 50 pg for chlorinated HVOCs with the additional advantage that calibration is almost independent on different compounds of the same halogen. In contrast to that detection limits for ECD vary for the different halogenated compounds and lie in the range of 0.03-11 pg. The two-dimensional GC-ECD/ICP-MS instrumentation is compared with electron impact mass spectrometry (EI-MS) and microwave induced plasma atomic emission detection (MIP-AED). Even if EI-MS has additional power in identifying unknown peaks by its scan mode, the detection limits are much higher compared with GC-ECD/ICP-MS, whereas the selective ion monitoring mode (SIM) reaches similar detection limits. The MIP-AED detection limits are at the same level as EI-MS in the scan mode" |
Keywords: | "Air Pollutants/*analysis Gas Chromatography-Mass Spectrometry/instrumentation/*methods Hydrocarbons, Brominated/*analysis Hydrocarbons, Iodinated/*analysis Volatilization Water Pollutants, Chemical/*analysis;" |
Notes: | "MedlineSchwarz, A Heumann, K G eng Research Support, Non-U.S. Gov't Germany 2002/09/27 Anal Bioanal Chem. 2002 Sep; 374(2):212-9. doi: 10.1007/s00216-002-1422-8. Epub 2002 Aug 23" |