Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractPreconcentration and analysis of trace volatile carbonyl compounds    Next AbstractResponses of Fresh-Cut Strawberries to Ethanol Vapor Pretreatment: Improved Quality Maintenance and Associated Antioxidant Metabolism in Gene Expression and Enzyme Activity Levels »

Environ Sci Technol


Title:Robust nonfitting way to determine mass diffusivity and initial concentration for VOCs in building materials with accuracy estimation
Author(s):Li M;
Address:"School of Energy Science and Engineering, Central South University, Changsha 410083, China. cnlimin78@gmail.com"
Journal Title:Environ Sci Technol
Year:2013
Volume:20130802
Issue:16
Page Number:9086 - 9092
DOI: 10.1021/es401244g
ISSN/ISBN:1520-5851 (Electronic) 0013-936X (Linking)
Abstract:"This paper presents a novel procedure for estimating mass diffusivity and initial concentration for VOCs in building materials. In contrast to methods that fit data to an organic emission model, this new method determines these two parameters by two observations from a chamber test in a nonfitting and sequential way, which defines a well-posed problem and requires no iterative procedure as well as is robust to initial guess and random uncertainties. The most outstanding feature of this method is that multiple estimates of the parameters can be obtained when more than two experimental data are available; thus, these estimates constitute a sample of population of parameter estimates involving experimental errors. The averages of the sample can be regarded the best estimates of the parameters, and, more importantly, variances (standard deviations) and confidence intervals can be readily and naturally estimated making no assumption about the distribution of experimental errors. Two easy and direct ways are suggested for determining confidence limits: one is percentile method, and the other is the normal approximation. This feature highlights the major difference between the new method and common curve-fitting procedures that generally assume random errors being Gaussian distribution"
Keywords:"Construction Materials/*analysis *Models, Chemical Volatile Organic Compounds/*analysis;"
Notes:"MedlineLi, Min eng Validation Study 2013/07/23 Environ Sci Technol. 2013 Aug 20; 47(16):9086-92. doi: 10.1021/es401244g. Epub 2013 Aug 2"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 25-11-2024