Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractScreening of drugs that suppress Ste11 MAPKKK activation in yeast identified a c-Abl tyrosine kinase inhibitor    Next AbstractThe Schizosaccharomyces pombe mam2 gene encodes a putative pheromone receptor which has a significant homology with the Saccharomyces cerevisiae Ste2 protein »

Anal Sci


Title:Quantification of 23 Volatile Organic Compounds with a Single Reference Material Using Post-column Reaction Gas Chromatography Combined with a Stainless-steel Heating Furnace
Author(s):Kitamaki Y; Saito N; Sasaki N; Morita M; Sasaki T; Miyamoto H; Numata M; Ihara T;
Address:"National Metrology Institute of Japan (NMIJ), National Institute of Advanced Industrial Science and Technology (AIST), 1-1-1 Umezono, Tsukuba, Ibaraki, 305-8563, Japan. y-kitamaki@aist.go.jp. National Metrology Institute of Japan (NMIJ), National Institute of Advanced Industrial Science and Technology (AIST), 1-1-1 Umezono, Tsukuba, Ibaraki, 305-8563, Japan. Horiba Stec Co., Ltd., 11-5 Hokotate Kamitoba, Minami, Kyoto, 601-8116, Japan"
Journal Title:Anal Sci
Year:2021
Volume:20210205
Issue:8
Page Number:1185 - 1188
DOI: 10.2116/analsci.20N036
ISSN/ISBN:1348-2246 (Electronic) 0910-6340 (Linking)
Abstract:"We built a heating furnace using stainless-steel instead of aluminum in gas chromatography combined with an oxidation/reduction system; it increased the oxidation temperature to 650 degrees C. At 600 degrees C, it completely oxidized five organochlorine compounds. This system was applied to a standard solution of 23 volatile organic compounds. The analytical results of 20 hydrocarbon and organochlorine compounds showed good agreement with the expanded uncertainty (k = 2) of the reference values. Three organobromine compounds obtained values higher than the reference; this was investigated further"
Keywords:Post-column reaction gas chromatography organobromine compounds organochlorine compounds volatile organic compound;
Notes:"PubMed-not-MEDLINEKitamaki, Yuko Saito, Naoki Sasaki, Nanako Morita, Mariko Sasaki, Tomohiro Miyamoto, Hideaki Numata, Masahiko Ihara, Toshihide eng Switzerland 2021/02/09 Anal Sci. 2021 Aug 10; 37(8):1185-1188. doi: 10.2116/analsci.20N036. Epub 2021 Feb 5"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 19-12-2024