Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractSilicon photonics waveguide array sensor for selective detection of VOCs at room temperature    Next AbstractSimultaneous removal of volatile organic compounds (VOCs) and nitrogen: batch test »

Mikrochim Acta


Title:A selective chemiresistive sensor for the cancer-related volatile organic compound hexanal by using molecularly imprinted polymers and multiwalled carbon nanotubes
Author(s):Janfaza S; Banan Nojavani M; Nikkhah M; Alizadeh T; Esfandiar A; Ganjali MR;
Address:"Department of Nanobiotechnology, Faculty of Biological Sciences, Tarbiat Modares University, Jalal Ale Ahmad Highway, Tehran, 14117, Iran. Department of Biomaterials, Faculty of Interdisciplinary Sciences, Tarbiat Modares University, Jalal Ale Ahmad Highway, Tehran, 14117, Iran. Department of Nanobiotechnology, Faculty of Biological Sciences, Tarbiat Modares University, Jalal Ale Ahmad Highway, Tehran, 14117, Iran. m_nikkhah@modares.ac.ir. Department of Analytical Chemistry, Faculty of Chemistry, University College of Science, University of Tehran, P.O. Box 14155-6455, Tehran, Iran. Department of Physics, Sharif University of Technology, P.O. Box 11155-9161, Tehran, Iran. Condensed Matter National Laboratory, Institute for Research in Fundamental Sciences, P.O. Box 1956838861, Tehran, Iran"
Journal Title:Mikrochim Acta
Year:2019
Volume:20190201
Issue:3
Page Number:137 -
DOI: 10.1007/s00604-019-3241-z
ISSN/ISBN:1436-5073 (Electronic) 0026-3672 (Linking)
Abstract:"A chemiresistive sensor is described for the lung cancer biomarker hexanal. A composite consisting of molecularly imprinted polymer nanoparticles and multiwalled carbon nanotubes was used in the sensor that is typically operated at a voltage of 4 V and is capable of selectively sensing gaseous hexanal at room temperature. It works in the 10 to 200 ppm concentration range and has a 10 ppm detection limit (at S/N = 3). The sensor signal recovers to a value close to its starting value without the need for heating even after exposure to relatively high levels of hexanal. Graphical abstract Schematic presentation of a chemiresistive sensor for detection of hexanal, a cancer biomarker. The hexanal-imprinted polymeric nanoparticles were synthesized, mixed with multiwalled carbon nanotubes and coated on the surface of an interdigitated electrode to produce a nanocomposite chemiresistor gas sensor for hexanal"
Keywords:"Aldehydes/*analysis Biomarkers, Tumor/analysis Biosensing Techniques Electrochemical Techniques Electrodes Gases/chemistry Humans Limit of Detection Lung Neoplasms/*diagnosis Methacrylates/chemistry *Molecular Imprinting Nanocomposites/chemistry Nanoparti;"
Notes:"MedlineJanfaza, Sajjad Banan Nojavani, Maryam Nikkhah, Maryam Alizadeh, Taher Esfandiar, Ali Ganjali, Mohammad Reza eng Austria 2019/02/02 Mikrochim Acta. 2019 Feb 1; 186(3):137. doi: 10.1007/s00604-019-3241-z"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 26-11-2024