Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractSwitchable sniff-cam (gas-imaging system) based on redox reactions of alcohol dehydrogenase for ethanol and acetaldehyde in exhaled breath    Next AbstractRevisiting the Physicochemical Properties and Applications of Deep Eutectic Solvents »

ACS Sens


Title:Transcutaneous Blood VOC Imaging System (Skin-Gas Cam) with Real-Time Bio-Fluorometric Device on Rounded Skin Surface
Author(s):Iitani K; Toma K; Arakawa T; Mitsubayashi K;
Address:"Japan Society for the Promotion of Science , 5-3-1 Kojimachi, Chiyoda-ku , Tokyo 102-0083 , Japan. Department of Life Science and Medical Bioscience, Graduate School of Advanced Science and Engineering , Waseda University (TWIns) , 2-2 Wakamatsu-cho, Shinjuku-ku , Tokyo 162-8480 , Japan. Department of Biomedical Devices and Instrumentation, Institute of Biomaterials and Bioengineering , Tokyo Medical and Dental University (TMDU) , 2-3-10 Kanda-Surugadai, Chiyoda-ku , Tokyo 101-0062 , Japan"
Journal Title:ACS Sens
Year:2020
Volume:20191224
Issue:2
Page Number:338 - 345
DOI: 10.1021/acssensors.9b01658
ISSN/ISBN:2379-3694 (Electronic) 2379-3694 (Linking)
Abstract:"A skin-gas cam that allows continuous imaging of transcutaneous blood volatile organic compounds (VOCs) emanated from human skin was developed. The skin-gas cam is able to reveal the relationship between the local skin conditions and transcutaneous blood VOCs in the field of volatile metabolomics (volatolomics). A ring-type ultraviolet (UV) light-emitting diode was mounted around a camera lens as an excitation light source, which enabled the simultaneous excitation and imaging of fluorescence. A nicotinamide adenine dinucleotide (NAD)-dependent alcohol dehydrogenase (ADH) was used to detect ethanol as a model sample. When gaseous ethanol was applied to an ADH-immobilized mesh that was wetted with an oxidized NAD solution placed in front of the camera, a reduced form of NAD (NADH) was produced through an ADH-mediated reaction. NADH emits fluorescence by UV excitation, and thus, the concentration distribution of ethanol was visualized by measuring the distribution of the fluorescence light intensity from NADH on the ADH-immobilized mesh surface. In this study, a new gas application method that mimicked the release mechanism of transcutaneous gas for quantification of the transcutaneous gas concentration was evaluated. Also, spatiotemporal changes of transcutaneous ethanol for various body parts were measured. As a result, we revealed a relationship between local skin conditions and VOCs that could not be observed previously. In particular, we demonstrated the facile measurement of transdermal gases from around the ear where capillaries are densely distributed below a thin stratum corneum"
Keywords:"Blood Gas Monitoring, Transcutaneous/*methods Fluorometry/*methods Humans Skin/*chemistry Volatile Organic Compounds/*chemistry biosensor enzyme fluorescence spatiotemporal imaging transcutaneous volatile volatolomics;"
Notes:"MedlineIitani, Kenta Toma, Koji Arakawa, Takahiro Mitsubayashi, Kohji eng Research Support, Non-U.S. Gov't 2019/12/26 ACS Sens. 2020 Feb 28; 5(2):338-345. doi: 10.1021/acssensors.9b01658. Epub 2019 Dec 24"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 25-12-2024