Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractRAP-1 factor is necessary for DNA loop formation in vitro at the silent mating type locus HML    Next AbstractRobustness validation of a test procedure for the determination of the radon-222 exhalation rate from construction products in VOC emission test chambers »

Radiat Prot Dosimetry


Title:Use of Commercial Radon Monitors for Low Level Radon Measurements in Dynamically Operated Voc Emission Test Chambers
Author(s):Hofmann M; Richter M; Jann O;
Address:"Bundesanstalt fur Materialforschung und -prufung (BAM), Division 4.2 Materials and Air Pollutants, Unter den Eichen 44-46, 12203 Berlin, Germany"
Journal Title:Radiat Prot Dosimetry
Year:2017
Volume:177
Issue:1-Feb
Page Number:16 - 20
DOI: 10.1093/rpd/ncx137
ISSN/ISBN:1742-3406 (Electronic) 0144-8420 (Linking)
Abstract:"Compared to the intended EU reference level of 300 Bq m-3 for indoor radon concentrations, the contribution of building materials appears to be low. Considering the recommended limit of 100 Bq m-3 by WHO, their contribution is supposed to be relevant, especially at low air exchange rates. This study as part of a two-part research project investigated the suitability of direct low level 222Rn measurement under simulated indoor conditions with commercial radon monitors and dynamically operated emission test chambers. Active measuring devices based on ionisation or scintillation chambers with 1-sigma uncertainties below 8.6% at 20 Bq m-3 were found to be best suitable for a practical test procedure for the determination of radon exhalation rates of building materials. For the measurement of such low concentrations, the knowledge of the accurate device background level is essential"
Keywords:"Air Pollutants, Radioactive/*analysis Air Pollution, Indoor/*analysis Construction Materials Equipment Design Humidity Radiation Monitoring/*instrumentation Radon/*analysis Temperature Volatile Organic Compounds;"
Notes:"MedlineHofmann, M Richter, M Jann, O eng England 2017/10/06 Radiat Prot Dosimetry. 2017 Nov 1; 177(1-2):16-20. doi: 10.1093/rpd/ncx137"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 16-11-2024