Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractVirus Infection of Plants Alters Pollinator Preference: A Payback for Susceptible Hosts?    Next AbstractPrevalence of sensitization to the predatory mite Amblyseius cucumeris as a new occupational allergen in horticulture »

Anal Chim Acta


Title:Recovery of phosphonate surface contaminants from glass using a simple vacuum extractor with a solid-phase microextraction fiber
Author(s):Groenewold GS; Scott JR; Rae C;
Address:"Interfacial Chemistry, Idaho National Laboratory, Idaho Falls, 83415-2208, USA. gary.groenewold@inl.gov"
Journal Title:Anal Chim Acta
Year:2011
Volume:20110427
Issue:1-Feb
Page Number:38 - 47
DOI: 10.1016/j.aca.2011.04.034
ISSN/ISBN:1873-4324 (Electronic) 0003-2670 (Linking)
Abstract:"Recovery of chemical contaminants from fixed surfaces for analysis can be challenging, particularly if it is not possible to acquire a solid sample to be taken to the laboratory. A simple device is described that collects semi-volatile organic compounds from fixed surfaces by creating an enclosed volume over the surface, then generating a modest vacuum. A solid-phase microextraction (SPME) fiber is then inserted into the evacuated volume where it functions to sorb volatilized organic contaminants. The device is based on a syringe modified with a seal that is used to create the vacuum, with a perforable plunger through which the SPME fiber is inserted. The reduced pressure speeds partitioning of the semi-volatile compounds into the gas phase and reduces the boundary layer around the SPME fiber, which enables a fraction of the volatilized organics to partition into the SPME fiber. After sample collection, the SPME fiber is analyzed using conventional gas chromatography/mass spectrometry. The methodology has been used to collect organophosphorus compounds from glass surfaces, to provide a simple test for the functionality of the devices. Thirty minute sampling times (DeltaT(vac)) resulted in fractional recovery efficiencies that ranged from 10(-3) to >10(-2), and in absolute terms, collection of low nanograms was demonstrated. Fractional recovery values were positively correlated to the vapor pressure of the compounds being sampled. Fractional recovery also increased with increasing DeltaT(vac) and displayed a roughly logarithmic profile, indicating that an operational equilibrium is being approached. Fractional recovery decreased with increasing time between exposure and sampling; however, recordable quantities of the phosphonates could be collected three weeks after exposure"
Keywords:
Notes:"PubMed-not-MEDLINEGroenewold, Gary S Scott, Jill R Rae, Catherine eng Netherlands 2011/06/07 Anal Chim Acta. 2011 Jul 4; 697(1-2):38-47. doi: 10.1016/j.aca.2011.04.034. Epub 2011 Apr 27"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 25-12-2024