Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractOn the use of Carbograph 5TD as an adsorbent for sampling VVOCs: validation of an analytical method    Next AbstractSeminal vesicle and preputial gland response to steroids in adult male mice is influenced by prior intrauterine position »

Anal Chim Acta


Title:"Selection of gas standards, gas chromatography column and adsorbents for the measurement of very volatile organic compounds (C(1)-C(6)) in indoor air"
Author(s):Even M; Juritsch E; Richter M;
Address:"Bundesanstalt fur Materialforschung und -prufung (BAM), Division 4.2 - Materials and Air Pollutants, Unter den Eichen 87, 12205, Berlin, Germany. Bundesanstalt fur Materialforschung und -prufung (BAM), Division 4.2 - Materials and Air Pollutants, Unter den Eichen 87, 12205, Berlin, Germany. Electronic address: matthias.richter@bam.de"
Journal Title:Anal Chim Acta
Year:2023
Volume:20221029
Issue:
Page Number:340561 -
DOI: 10.1016/j.aca.2022.340561
ISSN/ISBN:1873-4324 (Electronic) 0003-2670 (Linking)
Abstract:"The ISO 16000-6 standard gives directions to adapt the analysis of volatile organic compounds (VOCs) in indoor and test chamber air to very volatile organic compounds (VVOCs). The same techniques with sorbent-based active sampling, thermal desorption and gas chromatography coupled with mass spectrometry (TD-GC/MS) should be used. However, VVOCs require gaseous standards, an adapted GC column and a reliable sampling adsorbent. This work presents experimental results to tackle those three experimental gaps. A stable standard gas mixture containing 47 VVOCs, 13 VOCs and an internal standard was successfully generated. It was employed to study the suitability of seven types of chromatography columns. The use of PLOT (Porous Layer Open Tubular) columns such as PoraBOND Q is well suitable for VVOC analysis. The recoveries of the 60 analytes on a total of 16 adsorbents and their combinations were determined: A combination of the graphitized carbon black Carbograph 5TD 40/60 and the carbon molecular sieve Carbosieve SII showed great recoveries for all analytes. Carbon molecular sieves adsorb water which can impair the analysis. A dry purge of the multi-sorbent in the sampling direction led to a complete water removal and promising recoveries of the analytes"
Keywords:"*Volatile Organic Compounds *Air Pollution, Indoor Gas Chromatography-Mass Spectrometry Gases Water Carbon Air sampling Gas chromatography Iso 16000-6 Thermal desorption Voc Vvoc;"
Notes:"MedlineEven, Morgane Juritsch, Elevtheria Richter, Matthias eng Netherlands 2022/12/05 Anal Chim Acta. 2023 Jan 15; 1238:340561. doi: 10.1016/j.aca.2022.340561. Epub 2022 Oct 29"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 25-12-2024