Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractPhotocatalytic oxidation of volatile organic compounds using fluorescent visible light    Next Abstract[Specificity of the response of monogamous and polygamous Scolytidae to the attraction exerted by digestive residues (feces)] »

J AOAC Int


Title:Single-Laboratory Validation of a Gas Chromatographic Method of Direct Determination of Volatile Compounds in Spirit Drinks: Need for an Improved Interlaboratory Study
Author(s):Charapitsa SV; Sytova SN; Korban AL; Sobolenko LN;
Address:"Belarusian State University, Institute for Nuclear Problems, Bobruyskaya St, 11, Minsk, Belarus"
Journal Title:J AOAC Int
Year:2019
Volume:20181116
Issue:2
Page Number:669 - 672
DOI: 10.5740/jaoacint.18-0258
ISSN/ISBN:1944-7922 (Electronic) 1060-3271 (Linking)
Abstract:"Background: The quality and safety control of an alcoholic drink is mainly the establishment of its chemical content, particularly the quantity of volatile compounds. Objective: A single-laboratory validation of a gas chromatographic method of direct determination of volatile compounds in spirit drinks was conducted. The discussed method applies ethanol, the major volatile component of an alcoholic beverage, as an internal standard. Possible algorithms of method validation based on interlaboratory study were proposed and described. Methods: Seven standard solutions of the following volatile compounds were prepared gravimetrically in 40% (v/v) water-ethanol solution: acetaldehyde, methyl acetate, ethyl acetate, methanol, 2-propanol, 1-propanol, isobutanol, 1-butanol, and isoamylol. Each sample was measured with the proposed method 30 times in repeatability conditions. Results: Flame ionization detector response was linearly correlated with assigned concentrations at a range of 2 to 5000 mg/L of absolute alcohol (AA) with coefficients of determination (R(2)) more than 0.995 for all analyzed components. Repeatability (RSD(r)
Keywords:"Alcoholic Beverages/*analysis Chromatography, Gas Laboratories Volatile Organic Compounds/*analysis;"
Notes:"MedlineCharapitsa, Siarhei V Sytova, Svetlana N Korban, Anton L Sobolenko, Lidia N eng Validation Study England 2018/11/18 J AOAC Int. 2019 Mar 1; 102(2):669-672. doi: 10.5740/jaoacint.18-0258. Epub 2018 Nov 16"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 19-12-2024