Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractAmbient air monitoring with Auto-gas chromatography running in trigger mode    Next AbstractCharacteristics of oily sludge combustion in circulating fluidized beds »

Anal Chim Acta


Title:Automatic alignment of infrared video frames for equipment leak detection
Author(s):Zhou L; Zeng Y;
Address:"Providence Engineering and Environmental Group LLC, Baton Rouge, LA, USA. limingzhou@providenceeng.com "
Journal Title:Anal Chim Acta
Year:2007
Volume:20061112
Issue:1
Page Number:223 - 227
DOI: 10.1016/j.aca.2006.11.026
ISSN/ISBN:1873-4324 (Electronic) 0003-2670 (Linking)
Abstract:"Petroleum refining and petrochemical industries start using infrared (IR) cameras to detect volatile organic compounds (VOC) leaking out of process equipment. However, further quantitative processing of these video image data or automatic recognition of VOC plumes are hindered by unaligned video frames owing to the slight vibrations of the camera. An automatic method is developed to align the IR video frames as a preprocessing procedure for other possible video processing methods. The alignment method is based on a two-dimensional spatial Fourier transform. The accuracy can reach fractional pixels in estimation of translational shift and 1-2 degrees for rotational shift. Temporal Fourier transform of actual industrial tests of IR videos is performed with both unaligned and aligned video frames. The results indicate that only after the alignment of the video frames, the camera motion interferences on VOC plume identification can be eliminated or minimized, and the VOC plume can be identified through investigating the characteristic flickering frequency power in the temporal Fourier transform. This alignment method provides a useful tool for IR or other optical video image data preprocessing purposes"
Keywords:"Algorithms *Artifacts Automation Computer Graphics Equipment Design Equipment Failure Image Enhancement Pattern Recognition, Automated Petroleum Photography Spectroscopy, Fourier Transform Infrared *Video Recording Volatilization;"
Notes:"MedlineZhou, Liming Zeng, Yousheng eng Netherlands 2007/03/28 Anal Chim Acta. 2007 Feb 12; 584(1):223-7. doi: 10.1016/j.aca.2006.11.026. Epub 2006 Nov 12"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 23-11-2024