Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractGeneralist and Specialist Mite Herbivores Induce Similar Defense Responses in Maize and Barley but Differ in Susceptibility to Benzoxazinoids    Next AbstractFactors affecting the exposure to physicochemical and microbiological pollutants in vehicle cabins while commuting in Lisbon »

Environ Technol


Title:Determination of low solvent concentration by nano-porous silicon photonic sensors using volatile organic compound method
Author(s):Bui H; Pham VH; Pham VD; Hoang THC; Pham TB; Do TC; Ngo QM; Nguyen TV;
Address:"Institute of Materials Science, Vietnam Academy of Science and Technology , Hanoi , Vietnam. Graduate University of Science and Technology, Vietnam Academy of Science and Technology , Hanoi , Vietnam. Thai Nguyen University of Education , Thai Nguyen City , Vietnam"
Journal Title:Environ Technol
Year:2019
Volume:20180516
Issue:26
Page Number:3403 - 3411
DOI: 10.1080/09593330.2018.1474268
ISSN/ISBN:1479-487X (Electronic) 0959-3330 (Linking)
Abstract:"A vast majority of the organic solvents used in industry and laboratories are volatile, hazardous and toxic organic compounds, they are considered as a potent problem for human health and a cause of environmental pollution. Although analytical laboratory methods can determine extremely low solvent concentration, the sensing method with low cost and high sensitivity remains a conundrum. This paper presents and compares three methods (volatile organic compound (VOC), liquid drop and saturated vapour pressure) for determination of organic solvents in a liquid environment by using photonic sensor based on nano-porous silicon (pSi) microcavity structures. Among those, the VOC method provides the highest sensitivity at low solvent volume concentrations because it can create a high vapour pressure of the analyte on the sensor surface owing to the capillary deposition of the organic solvent into the silicon pores. This VOC method consists of three steps: heating the solution with its particular boiling temperature, controlling the flowing gas through liquid and cooling sensor. It delivers the highest sensitivity of 6.9 nm/% at a concentration of 5% and the limit of detection (LOD) of pSi-sensor is 0.014% in case of ethanol in water when using an optical system with a resolution of 0.1 nm. Especially, the VOC method is capable of detecting low volume concentration of methanol in two tested ethanol solutions of 30% (v/v) and 45% (v/v) with the LOD of pSi-sensor up to 0.01% and 0.04%, respectively. This result will help pave a way to control the quality of contaminated liquor beverages"
Keywords:Humans Limit of Detection Porosity Silicon Solvents *Volatile Organic Compounds Volatile organic compound capillary deposition high sensitivity photonic sensor nano-porous silicon organic solvents;
Notes:"MedlineBui, Huy Pham, Van Hoi Pham, Van Dai Hoang, Thi Hong Cam Pham, Thanh Binh Do, Thuy Chi Ngo, Quang Minh Nguyen, Thuy Van eng England 2018/05/08 Environ Technol. 2019 Nov; 40(26):3403-3411. doi: 10.1080/09593330.2018.1474268. Epub 2018 May 16"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 25-12-2024