Sangyo Eiseigaku Zasshi


Title:[Clinical findings of the patients with sick building syndrome and the results of environmental measurement]
Author(s):Yoshida T; Ogawa M; Goto H; Ohshita A; Kurose N; Yokosawa F; Hirata M; Endo Y;
Address:"Environmental Health Research Center, Kansai Rosai Hospital. t.yoshida-0402@kanrou.net"
Journal Title:Sangyo Eiseigaku Zasshi
Year:2011
Volume:20110201
Issue:2
Page Number:25 - 32
DOI: 10.1539/sangyoeisei.b10011
ISSN/ISBN:1349-533X (Electronic) 1341-0725 (Linking)
Abstract:"OBJECTIVES: Although many survey reports on sick house syndrome have been published, few clinical studies have reported sick building syndrome (SBS) in Japan. We examined patients with SBS-like complaints by clinical observation and made environment measurements. METHODS: The subjects of our study were 11 office workers (2 men and 9 women) who visited our hospital because of poor physical condition after the construction and painting of a fireproof vault in their office. We performed a medical interview, biochemical examinations of blood, immunological tests, pulmonary function tests, and psychological tests. The environment in the office was evaluated 3 times at 27, 55, and 132 days after the cessation of vault construction. A questionnaire survey was distributed to the workers who did not visit our hospital. RESULTS: The workers resumed work 9 days after the end of construction: Shortly after the resumption of work, most of the workers smelled a bad odor, and complained of headache, malaise, disturbed concentration, and eye irritation. Acrylic resin paint was used for painting the vault, and the concentrations of toluene, xylene, and total volatile organic compounds (T-VOC) on day 27 after painting were 2,972, 2,610, and 7,100 mug/m(3), respectively. One hundred and thirty-two days after painting, the concentrations of toluene, xylene, and T-VOC decreased to unscented levels of 78, 113, and 261 mug/m(3), respectively. CONCLUSION: Seven females among the eleven patients were diagnosed as having SBS on the basis of the time of the onset of the symptoms, negative results of allergy and other organic diseases, and the results of the environment measurements. From the responses of the other workers (22 men and 1 woman) to the survey questionnaire, the development and the disappearance of complaints, such as bad odor and unpleasantness, agreed with change of the level of toluene in the vault, which confirmed the validity of the SBS diagnosis"
Keywords:"Air Pollution, Indoor/*adverse effects Cohort Studies Environmental Monitoring/*methods Epidemiological Monitoring Eye Diseases/chemically induced/epidemiology Fatigue/chemically induced/epidemiology Female Headache/chemically induced/epidemiology Humans;"
Notes:"MedlineYoshida, Tatsuo Ogawa, Masanori Goto, Hiroyuki Ohshita, Ayumi Kurose, Naoko Yokosawa, Fumiko Hirata, Mamoru Endo, Yoko jpn English Abstract Japan 2011/02/08 Sangyo Eiseigaku Zasshi. 2011; 53(2):25-32. doi: 10.1539/sangyoeisei.b10011. Epub 2011 Feb 1"

 