Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractFlexible Chemiresistive Cyclohexanone Sensors Based on Single-Walled Carbon Nanotube-Polymer Composites    Next AbstractMuch concern but little research on semiconductor occupational health issues »

Environ Sci Pollut Res Int


Title:Indoor air quality differences between urban and rural preschools in Korea
Author(s):Yoon C; Lee K; Park D;
Address:"Department of Environmental Health, Seoul National University, 599 Gwanak-ro, Gwanak-gu, Seoul, 151-742, South Korea. csyoon@snu.ac.kr"
Journal Title:Environ Sci Pollut Res Int
Year:2011
Volume:20100729
Issue:3
Page Number:333 - 345
DOI: 10.1007/s11356-010-0377-0
ISSN/ISBN:1614-7499 (Electronic) 0944-1344 (Linking)
Abstract:"BACKGROUND, AIMS, AND SCOPE: Preschool indoor air quality (IAQ) is believed to be different from elementary school or higher school IAQ and preschool is the first place for social activity. Younger children are more susceptible than higher-grade children and spend more time indoors. The purpose of this study was to compare the indoor air quality by investigating the concentrations of airborne particulates and gaseous materials at preschools in urban and rural locations in Korea. METHODS: We investigated the concentrations of airborne particulates and gaseous materials in 71 classrooms at 17 Korean preschools. For comparison, outdoor air was sampled simultaneously with indoor air samples. Airborne concentrations of total suspended particulates, respirable particulates, lead, asbestos, total volatile organic compounds and components, formaldehyde, and CO(2) were measured with National Institute for Occupational Safety and Health and/or Environmental Protection Agency analytical methods. RESULTS: The concentration profiles of the investigated pollutants in indoor and urban settings were higher than those in outdoor and rural areas, respectively. The ratios of indoor/outdoor concentrations (I/O) of particulates and gaseous pollutants were characterized in urban and rural preschools. Total dust concentration was highest in urban indoor settings followed by urban outdoor, rural indoor, and rural outdoor locations with an I/O ratio of 1.37 in urban and 1.35 in rural areas. Although I/O ratios of lead were close to 1, lead concentrations were much higher in urban than in rural areas. The I/O ratio of total VOCs was 2.29 in urban and 2.52 in rural areas, with the highest level in urban indoor settings. The I/O ratio of formaldehyde concentrations was higher in rural than in urban areas because the outdoor rural level was much lower than the urban concentration. Since an I/O ratio higher than 1 implies the presence of indoor sources, we concluded that there are many indoor sources in preschools. CONCLUSIONS: We confirmed that pollutants in indoor and urban settings were higher than those in outdoor and rural areas, respectively. Preschool children are expected to spend more time inside preschool facilities and therefore to be more exposed to pollutants. As far as we know, preschool IAQ is different from elementary school or higher school IAQ. Also, they are more vulnerable than higher-grade children. We found that the indoor and urban concentration profiles of the studied pollutants in preschools were higher than those in outdoor and rural areas. We believe that our findings may be useful for understanding the potential health effects of exposure and intervention studies in preschools"
Keywords:"Air Pollutants/*analysis Air Pollution, Indoor/*analysis/statistics & numerical data Asbestos/analysis Carbon Dioxide/analysis Child, Preschool Cities Environmental Monitoring/methods Formaldehyde/analysis Humans Inhalation Exposure/analysis/statistics &;"
Notes:"MedlineYoon, Chungsik Lee, Kiyoung Park, Donguk eng Comparative Study Germany 2010/07/30 Environ Sci Pollut Res Int. 2011 Mar; 18(3):333-45. doi: 10.1007/s11356-010-0377-0. Epub 2010 Jul 29"

 