Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractAmmonium carbonate is more attractive than apple and hawthorn fruit volatile lures to Rhagoletis pomonella (Diptera: Tephritidae) in Washington State    Next AbstractHeadspace solid-phase microextraction analysis of volatile components in Phalaenopsis Nobby's Pacific Sunset »

World J Orthop


Title:Analysis of electrocautery smoke released from the tissues frequently cut in orthopedic surgeries
Author(s):Yeganeh A; Hajializade M; Sabagh AP; Athari B; Jamshidi M; Moghtadaei M;
Address:"Department of Orthopaedics Surgery, Rasoul Akram Hospital, Iran University of Medical Sciences, Tehran 1445613131, Iran. Department of Orthopaedics Surgery, Shahid Mohammadi Hospital, Hormozgan University of Medical Sciences, Hormozgan, Bandarabbas 1445613131, Iran. Department of Chemistry, Payam-e-Nour University, Ghazvin 1445613131, Iran. Department of Orthopaedics Surgery, Rasoul Akram Hospital, Iran University of Medical Tehran ?ª-Province, Tehran, Satarkhan 1445613131, Iran. medicine.ortho@yahoo.com"
Journal Title:World J Orthop
Year:2020
Volume:20200318
Issue:3
Page Number:177 - 183
DOI: 10.5312/wjo.v11.i3.177
ISSN/ISBN:2218-5836 (Print) 2218-5836 (Electronic) 2218-5836 (Linking)
Abstract:"BACKGROUND: Electrosurgical smoke could be different by the device of cutting or the type of tissue that is being cut. AIM: To analyze the electrocautery smoke released from the tissues that are frequently cut in orthopedic surgeries. METHODS: The released smoke from electrocautery of five different tissue types (meniscus, ligament, adipose, muscle, and synovium) of five patients who underwent total knee arthroplasty were collected and analyzed for volatile organic compounds (VOCs) and 27 candidate polycyclic aromatic hydrocarbons (n = 25). Surgical smoke was produced with an electrocautery device for 4 min. RESULTS: None of the 27 evaluated polycyclic aromatic hydrocarbons compounds were detectable in electrocautery smoke collected from the surgical cutting of the different tissues. The number and identity of detected VOCs were similar between the patients but not between tissue types. The number of detected VOCs was the highest in synovial tissue (n = 21) and the lowest in the meniscus and adipose tissue (n = 12). ?ª+The number of toxic and/or carcinogenic VOCs were the most in the muscle and meniscus tissues (Toluene, Ethylbenzene, and Styrene). No toxic and/or carcinogenic VOCs were identified in the ligament and adipose tissue. CONCLUSION: Meniscus and muscle tissue are associated with the highest number of toxic and/or carcinogenic VOCs. Therefore, we recommend that surgeons avoiding the electrocautery of these tissues"
Keywords:Electrocautery smoke Polycyclic aromatic hydrocarbons Surgeon caution Volatile organic compounds;
Notes:"PubMed-not-MEDLINEYeganeh, Ali Hajializade, Mikaiel Sabagh, Alireza Pahlevan Athari, Babak Jamshidi, Mahbobeh Moghtadaei, Mehdi eng 2020/04/14 World J Orthop. 2020 Mar 18; 11(3):177-183. doi: 10.5312/wjo.v11.i3.177. eCollection 2020 Mar 18"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 23-11-2024