Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractAdsorption and regeneration on activated carbon fiber cloth for volatile organic compounds at indoor concentration levels    Next AbstractEffects of different permeable lenses on nitrobenzene transport during air sparging remediation in heterogeneous porous media »

J Air Waste Manag Assoc


Title:Investigation of the treatability of the primary indoor volatile organic compounds on activated carbon fiber cloths at typical indoor concentrations
Author(s):Yao M; Zhang Q; Hand DW; Perram DL; Taylor R;
Address:
Journal Title:J Air Waste Manag Assoc
Year:2009
Volume:59
Issue:7
Page Number:882 - 890
DOI: 10.3155/1047-3289.59.7.882
ISSN/ISBN:1096-2247 (Print) 1096-2247 (Linking)
Abstract:"Volatile organic compounds (VOCs) are a major concern for indoor air pollution because of the impacts on human health. In recent years, interest has increased in the development and design of activated carbon filters for removing VOCs from indoor air. Although extensive information is available on sources, concentrations, and types of indoor VOCs, there is little or no information on the performance of indoor air adsorption systems for removing low concentrations of primary VOCs. Filter designs need to consider various factors such as empty bed contact time, humidity effects, competitive adsorption, and feed concentration variations, whereas adsorption capacities of the indoor VOCs at the indoor concentration levels are important parameters for filter design. A preliminary assessment of the feasibility of using adsorption filters to remove low concentrations of primary VOCs can be performed. This work relates the information (including VOC classes in indoor air, the typical indoor concentrations, and the adsorption isotherms) with the design of a particular adsorbent/adsorbates system. As groundwork for filter design and development, this study selects the primary VOCs in indoor air of residences, schools, and offices in different geographical areas (North America, Europe, and Asia) on the basis of occurrence, concentrations, and health effects. Activated carbon fiber cloths (ACFCs) are chosen as the adsorbents of interest. It is demonstrated that the isotherm of a VOC (e.g., toluene on the ACFC) at typical indoor concentrations-parts per billion by volume (ppbv) level-is different than the isotherm at parts per million by volume (ppmv) levels reported in the publications. The isotherms at the typical indoor concentrations for the selected primary VOCs are estimated using the Dubinin-Radushkevitch equation. The maximum specific throughput for an indoor VOC removal system to remove benzene is calculated as a worst-case scenario. It is shown that VOC adsorption capacity is an important indicator of a filter's lifetime and needs to be studied at the appropriate concentration range. Future work requires better understanding of the realistic VOC concentrations and isotherms in indoor environments to efficiently utilize adsorbents"
Keywords:"Adsorption Air Pollution, Indoor/*analysis Carbon/*chemistry Carbon Fiber Environmental Restoration and Remediation/*methods Kinetics Volatile Organic Compounds/analysis/*chemistry;"
Notes:"MedlineYao, Meng Zhang, Qiong Hand, David W Perram, David L Taylor, Roy eng Evaluation Study Research Support, Non-U.S. Gov't 2009/08/04 J Air Waste Manag Assoc. 2009 Jul; 59(7):882-90. doi: 10.3155/1047-3289.59.7.882"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 22-11-2024