Title: | Assessment of pollutant emissions from dry-process photocopiers |
Address: | "CSIRO Building, Construction and Engineering, Victoria, Australia. Steve.Brown@dbce.csiro.au" |
DOI: | 10.1111/j.1600-0668.1999.00005.x |
ISSN/ISBN: | 0905-6947 (Print) 0905-6947 (Linking) |
Abstract: | "Processes involved in pollutant emissions from a dry-process photocopier have been investigated in a controlled room dynamic environmental chamber. Volatile organic compound (VOC) emissions occurred at a constant rate dependent on copy speed. However, VOC emission rates per copy were increased by increases in chamber temperature (e.g., a 20% increase resulted from increasing temperature from 23 degrees C to 32 degrees C) or changing from single- to double-sided operation (40% increase). Respirable particle emissions occurred under copier-idle mode (probably from residues in the machine) as well as with copying. No significant chamber sink effects were observed for VOCs or respirable particles. Small emissions of nitrogen dioxide, ozone and formaldehyde were observed but were difficult to interpret. A procedure for assessing pollutant emissions from photocopiers is recommended" |
Keywords: | "Air Pollution, Indoor/*analysis *Copying Processes Environmental Monitoring Equipment Safety Humans Occupational Exposure Particle Size Sick Building Syndrome/*etiology;" |
Notes: | "MedlineBrown, S K eng Research Support, Non-U.S. Gov't England 2000/01/29 Indoor Air. 1999 Dec; 9(4):259-67. doi: 10.1111/j.1600-0668.1999.00005.x" |