Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous Abstract"Inflammation markers in nasal lavage, and nasal symptoms in relation to relocation to a newly painted building: a longitudinal study"    Next Abstract"Changes of symptoms, tear film stability and eosinophilic cationic protein in nasal lavage fluid after re-exposure to a damp office building with a history of flooding" »

Int Arch Occup Environ Health


Title:"Nasal and ocular symptoms, tear film stability and biomarkers in nasal lavage, in relation to building-dampness and building design in hospitals"
Author(s):Wieslander G; Norback D; Nordstrom K; Walinder R; Venge P;
Address:"Department of Medical Sciences, Department of Occupational and Environmental Medicine, University Hospital, Uppsala University, S-751 85, Uppsala, Sweden. gunilla.wieslander@occmed.uu.se"
Journal Title:Int Arch Occup Environ Health
Year:1999
Volume:72
Issue:7
Page Number:451 - 461
DOI: 10.1007/s004200050398
ISSN/ISBN:0340-0131 (Print) 0340-0131 (Linking)
Abstract:"OBJECTIVES: To study the relationships between dampness in concrete floors and building design on the one hand, and symptoms and medical signs of the eyes and nose in hospital workers, on the other. METHODS: Four hospitals for geriatrics were selected to represent buildings with different ages and design, irrespective of symptom prevalence. The first building was built in 1925. The second, built in 1985, was known to have dampness in the floor. Conventional building techniques were used in the third building, built in 1993, and the last building was built in 1994, and was specially designed to include high ceilings, and minimal use of fluorescent lighting and interior plastic materials. The interior surfaces were painted with water-based beeswax glazing. All staff (n=95) working day shifts were invited to take part in a medical examination of the eyes and nose including acoustic rhinometry and nasal lavage, and a medical questionnaire, and 93% participated. Measurements of temperature, relative air humidity, air flow, illumination, volatile organic compounds (VOCs), molds, and bacteria were carried out in all buildings, together with measurements of formaldehyde, respirable dust, carbon monoxide (CO), carbon dioxide (CO(2)), nitrogen dioxide (NO(2)) and ozone. Statistical analyses were performed by bivariate analysis, and linear, ordinal, and logistic multiple regressions, adjusting for age, gender, tobacco smoking, atopy, and the perceived psychosocial work environment. RESULTS: Dampness in the upper concrete floor surface (75-84%), ammonia under the floor [3 parts per million (ppm)], and 2-ethyl-1-hexanol in the air were detected in the two buildings built in 1985 and 1993. Increased occurrences of ocular and nasal symptoms, an increased concentration of lysozyme in nasal lavage, and decreased tear film stability were found in the subjects working in the damp buildings. Those in the specially designed building had fewer ocular and nasal symptoms, and increased tear film stability. All buildings had low levels of formaldehyde, molds, bacteria, ozone, and NO(2). The lowest total concentration of VOCs, and the highest concentration of specific VOCs of microbial origin, were found in the building with special design. CONCLUSION: The study provides new evidence of the role of dampness-related alkaline degradation of di-(2-ethylhexyl) phthalate (DEHP) in polyvinyl chloride (PVC) building material. Emissions related to degradation of DEHP due to dampness in the floor, indicated by increased 2-ethyl-1-hexanol in the air, seem to increase both the secretion of lysozyme from the nasal mucosa and the occurrence of ocular and nasal symptoms. The indoor environment of the specially designed building with high ceilings and no fluorescent lighting or interior plastics seemed to have a positive influence on the nasal and ocular mucous membranes"
Keywords:"Adult Air Pollution, Indoor/analysis Biomarkers *Facility Design and Construction Female Floors and Floorcoverings *Hospitals Humans *Humidity Linear Models Logistic Models Male Middle Aged Nasal Lavage Fluid Prevalence Sick Building Syndrome/*epidemiolog;"
Notes:"MedlineWieslander, G Norback, D Nordstrom, K Walinder, R Venge, P eng Research Support, Non-U.S. Gov't Germany 1999/10/29 Int Arch Occup Environ Health. 1999 Oct; 72(7):451-61. doi: 10.1007/s004200050398"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 16-11-2024