Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractGeneration of an isogenic collection of yeast actin mutants and identification of three interrelated phenotypes    Next AbstractAllometric scaling of mammalian metabolism »

J Expo Anal Environ Epidemiol


Title:Development and testing of a whole-air sampler for measurement of personal exposure to volatile organic compounds
Author(s):Whitaker DA; Fortmann RC; Lindstrom AB;
Address:"Atmospheric Research and Exposure Assessment Laboratory, U.S. Environmental Protection Agency, Research Triangle Park, North Carolina 27711, USA"
Journal Title:J Expo Anal Environ Epidemiol
Year:1995
Volume:5
Issue:1
Page Number:89 - 100
DOI:
ISSN/ISBN:1053-4245 (Print) 1053-4245 (Linking)
Abstract:"A small and relatively lightweight (3.35 kg) whole-air (canister) sampler that can be worn to monitor personal exposures to volatile organic compounds was developed and evaluated. The prototype personal whole-air sampler (PWAS) consists of a 1-l canister, a mass flow controller, two 1.3 amp hour batteries, a DC/DC converter, and an electronics module with a digital display for the sampling set point, actual flow rate, and battery voltage. The sampler (25.5 x 22.5 x 7.5 cm) fits into a laptop computer carrying case and is able to collect a 900 ml sample at a linear flow rate over 12-16 hours. Laboratory tests demonstrated that the sample flow rate was not affected by temperature or the activity of the person wearing the sampler. Recoveries of methylene chloride, chloroform, 1,1,1-trichloroethane, benzene, n-octane, o-xylene, n-decane, and p-dichlorobenzene averaged 89% or better for three final prototype samplers. Recoveries were slightly lower for vinyl chloride (74%) and n-dodecane (82%). The precision for the three prototypes was excellent during laboratory tests with the coefficient of variation (CV) < 10% for all the test compounds. Although the unit was designed for use as a personal whole-air sampling system, it can also be used as an extremely compact microenvironmental whole-air sampler"
Keywords:Environmental Exposure/*analysis Environmental Monitoring/*instrumentation Equipment Design Humans Hydrocarbons/*isolation & purification Reproducibility of Results;
Notes:"MedlineWhitaker, D A Fortmann, R C Lindstrom, A B eng Research Support, U.S. Gov't, Non-P.H.S. England 1995/01/01 J Expo Anal Environ Epidemiol. 1995 Jan-Mar; 5(1):89-100"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 01-07-2024