« Previous AbstractCorrelation of low-volatile organic chlorine (LVOCl) and PCDD/Fs in various municipal waste incinerators (MWIs)    Next AbstractEnhancement of the luteinising hormone surge by male olfactory signals is associated with anteroventral periventricular Kiss1 cell activation in female rats »

Anal Chim Acta


Title:Metrological effectiveness of an analytical method for volatile organic compounds standard materials using post-column reaction GC/FID system
Author(s):Watanabe T; Kato K; Tsunoda K; Maeda T;
Address:"Organic Standards Section 1, Organic Analytical Chemistry Division, National Metrology Institute of Japan, National Institute of Advanced Industrial Science and Technology, Tsukuba, Ibaraki 305-8563, Japan. watanabe-takuro@aist.go.jp"
Journal Title:Anal Chim Acta
Year:2008
Volume:20080404
Issue:1
Page Number:26 - 29
DOI: 10.1016/j.aca.2008.03.059
ISSN/ISBN:1873-4324 (Electronic) 0003-2670 (Linking)
Abstract:"The metrological effectiveness of an analytical method using the post-column reaction GC/FID system was evaluated. The SI-traceable certified reference material (CRM), the eight ester phthalates mixture standard solution, was used as a sample. We assigned specific value to n-eicosane and it was used as an internal standard. A known quantity of n-eicosane was added to the CRM, and the mixture was measured with the post-column reaction GC/FID system. Six phthalate esters were chromatographically separated and determined. The assigned values by our system are in good agreement with the certified values of the CRM, and the combined uncertainties of the measurements by the present system were better than those of the CRM. Our method is classified as a primary ratio method and the specific values of many organic compounds can be assigned very precisely by using a small number of reference materials. Also, the method can make it possible to avoid the purity determination of raw materials and directly to assign their specific values after the preparation of the standard mixture. Conclusively, this post-column reaction GC/FID system is very effective for the chemical metrology"
Keywords:
Notes:"PubMed-not-MEDLINEWatanabe, Takuro Kato, Kenji Tsunoda, Kin-ichi Maeda, Tsuneaki eng Netherlands 2008/06/10 Anal Chim Acta. 2008 Jun 30; 619(1):26-9. doi: 10.1016/j.aca.2008.03.059. Epub 2008 Apr 4"

 