Title: | Identifying an unknown compound in flue gas of semiconductor industry - Forensics of a perfluorocarbon |
Author(s): | Wang CH; Huang CY; Yak HK; Hsieh HC; Wang JL; |
Address: | "Center for Environmental Studies, National Central University, Taoyuan, 320, Taiwan. Department of Chemistry, National Central University, Taoyuan, 320, Taiwan. Department of Chemistry, Chung Yuan Christian University, Taoyuan, 320, Taiwan. Department of Chemistry, National Central University, Taoyuan, 320, Taiwan. Electronic address: cwang@cc.ncu.edu.tw" |
DOI: | 10.1016/j.chemosphere.2020.128504 |
ISSN/ISBN: | 1879-1298 (Electronic) 0045-6535 (Linking) |
Abstract: | "This study investigated the source of a false positive signal in the measurement of total non-methane organic compounds (TNMOCs) by an on-line analyzer based on flame ionization detection (FID) in the flue gas released from a semiconductor fabrication plant. Since no release of volatile organic compounds (VOCs) into the waste gas stream in acid/base ventilation was assured by the plant authority, the positive detection of VOCs became a subject of dispute. In addition to the TNMOC analysis of 5 samples, the investigation used the method that coupled thermal desorption (TD) with gas chromatography mass spectrometry (GC/MS), dubbed TD-GC/MS, to identify the substance that produced the FID signals of TNMOCs. The waste gas was collected with sampling canisters and analyzed by in-laboratory TD-GC/MS. However, mass scanning from 45 to 250 m/z to remove interference from air matrix of O(2), N(2) and CO(2) forbid detecting any ion fragments smaller than 45 m/z and, thus, led to poor match in mass (MS) library search. As a result, a highly retentive porous layer open tubular (PLOT) capillary column was employed to separate the unknown away from the air peak. The success of acquiring all key ion fragments of 31, 50, 69, and 131 m/z resulted in an excellent match with octafluorocyclobutane (C(4)F(8)) in the NIST database. A gas standard was then prepared and injected to confirm the identity of C(4)F(8) by the identical mass spectrum and GC retention time. The concentrations of C(4)F(8) found in the 5 flue gas samples varying from 3.32 to 6.21 ppmv were very close to the NMOC range of 3.48-6.62 ppmv as reported by the TNMOC analyzer, proving that the FID signals observed from TNMOC method were mostly produced from C(4)F(8)(.) Consequently, the method of TD-GC/MS would be an ideal method to pre-screen the presence of PFCs before a non-distinguishable TNMOC analyzer is applied to approximate the VOC level as part of the integrated effort to monitor VOC in flue gas" |
Keywords: | Flame Ionization *Fluorocarbons Gas Chromatography-Mass Spectrometry Semiconductors *Volatile Organic Compounds/analysis Chemical vapor deposition (CVD) Non-methane organic compounds (NMOCs) Thermal desorption-gas chromatography mass spectrometry (TD-GC/M; |
Notes: | "MedlineWang, Chieh-Heng Huang, Chih-Ying Yak, Hwa-Kwang Hsieh, Hsin-Cheng Wang, Jia-Lin eng England 2020/10/17 Chemosphere. 2021 Feb; 264(Pt 2):128504. doi: 10.1016/j.chemosphere.2020.128504. Epub 2020 Oct 6" |