Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractHerbivore-Dependent Induced Volatiles in Pear Plants Cause Differential Attractive Response by Lacewing Larvae    Next AbstractDetection of volatile organic compounds using flexible gas sensing devices based on tungsten oxide nanostructures functionalized with Au and Pt nanoparticles »

Talanta


Title:Fully automated ionic liquid-based headspace single drop microextraction coupled to GC-MS/MS to determine musk fragrances in environmental water samples
Author(s):Vallecillos L; Pocurull E; Borrull F;
Address:"Department of Analytical Chemistry and Organic Chemistry, Universitat Rovira i Virgili, Sescelades Campus, Marcel li Domingo s/n, Tarragona 43007, Spain"
Journal Title:Talanta
Year:2012
Volume:20120801
Issue:
Page Number:824 - 832
DOI: 10.1016/j.talanta.2012.07.036
ISSN/ISBN:1873-3573 (Electronic) 0039-9140 (Linking)
Abstract:"A fully automated ionic liquid-based headspace single drop microextraction (IL-HS-SDME) procedure has been developed for the first time to preconcentrate trace amounts of ten musk fragrances extensively used in personal care products (six polycyclic musks, three nitro musks and one polycyclic musk degradation product) from wastewater samples prior to analysis by gas chromatography and ion trap tandem mass spectrometry (GC-IT-MS/MS). Due to the low volatility of the ILs, a large internal diameter liner (3.4 mm i.d.) was used to improve the ILs evaporation. Furthermore, a piece of glass wool was introduced into the liner to avoid the entrance of the ILs in the GC column and a guard column was used to prevent analytical column damages. The main factors influencing the IL-HS-SDME were optimized. For all species, the highest enrichments factors were achieved using 1 muL of 1-octyl-3-methylimidazolium hexafluorophosphate ([OMIM][PF(6)]) ionic liquid exposed in the headspace of 10 mL water samples containing 300 g L(-1) of NaCl and stirred at 750 rpm and 60 degrees C for 45 min. All compounds were determined by direct injection GC-IT-MS/MS with a chromatographic time of 19 min. Method detection limits were found in the low ng mL(-1) range between 0.010 ng mL(-1) and 0.030 ng mL(-1) depending on the target analytes. Also, under optimized conditions, the method gave good levels of intra-day and inter-day repeatabilities in wastewater samples with relative standard deviations varying between 3% and 6% and 5% and 11%, respectively (n=3, 1 ng mL(-1)). The applicability of the method was tested with different wastewater samples from influent and effluent urban wastewater treatment plants (WWTPs) and one potable treatment plant (PTP). The analysis of influent urban wastewater revealed the presence of galaxolide and tonalide at concentrations of between 2.10 ng mL(-1) and 0.29 ng mL(-1) and 0.32 ng mL(-1) and
Keywords:
Notes:"PubMed-not-MEDLINEVallecillos, Laura Pocurull, Eva Borrull, Francesc eng Research Support, Non-U.S. Gov't Netherlands 2012/09/13 Talanta. 2012 Sep 15; 99:824-32. doi: 10.1016/j.talanta.2012.07.036. Epub 2012 Aug 1"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 22-11-2024