Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractImpact of stressors in the aviation environment on xenobiotic dosimetry in humans: physiologically based prediction of the effect of barometric pressure or altitude    Next AbstractA novel strategy for the isolation of luxI homologues: evidence for the widespread distribution of a LuxR:LuxI superfamily in enteric bacteria »

Anal Bioanal Chem


Title:Hanging drop cathode-atmospheric pressure glow discharge as a new method of sample introduction for inductively coupled plasma-optical emission spectrometry
Author(s):Swiderski K; Welna M; Greda K; Pohl P; Jamroz P;
Address:"Faculty of Chemistry, Department of Analytical Chemistry and Chemical Metallurgy, Wroclaw University of Science and Technology, Wybrzeze Stanislawa Wyspianskiego 27, 50-370, Wroclaw, Poland. krzysztof.swiderski@pwr.edu.pl. Faculty of Chemistry, Department of Analytical Chemistry and Chemical Metallurgy, Wroclaw University of Science and Technology, Wybrzeze Stanislawa Wyspianskiego 27, 50-370, Wroclaw, Poland"
Journal Title:Anal Bioanal Chem
Year:2020
Volume:20200511
Issue:18
Page Number:4211 - 4219
DOI: 10.1007/s00216-020-02685-7
ISSN/ISBN:1618-2650 (Electronic) 1618-2642 (Print) 1618-2642 (Linking)
Abstract:"This work reports the use of hanging drop cathode-atmospheric pressure glow discharge (HDC-APGD) as a new method of sample introduction for inductively coupled plasma-optical emission spectrometry (ICP-OES). The developed arrangement was characterized by a low sample uptake (0.56 mL min(-1)) and the fact that the entire sample solution volume was consumed by the discharge. This resulted in a very high transport efficiency of analytes from the sample solution into the ICP torch (usually > 80%). Under the optimal operating conditions of HDC-APGD, intensities of emission lines of studied elements were, on average, 2 times higher as compared to those obtained with conventional pneumatic nebulization (PN). Moreover, in the case of I and Y, the observed signal enhancements were even higher, i.e., 6.2 and 6.1 times, respectively. It was also shown that in the case of B and some elements that are known to form different volatile species (Ag, Bi, Cd, Hg, Os, Pb, and Se), the presence of low molecular weight organic compounds in the sample solution, i.e., CH(3)OH, C(2)H(5)OH, HCOOH, CH(3)COOH, or HCHO, resulted in the additional enhancement of their signals. It was especially evident in the case of Hg for which a 8.6-fold signal enhancement in the presence of HCOOH was noticed. The system presented herein was distinguished from other competitive APGD-type discharges because it could be successfully used for the determination of a vast group of elements, including alkali metals, alkaline earth metals, transition metals, and non-metals"
Keywords:Atmospheric pressure glow discharge Hanging drop cathode Inductively coupled plasma Optical emission spectrometry Sample introduction;
Notes:"PubMed-not-MEDLINESwiderski, Krzysztof Welna, Maja Greda, Krzysztof Pohl, Pawel Jamroz, Piotr eng 2018/29/N/ST4/02186/Narodowe Centrum Nauki/ Germany 2020/05/13 Anal Bioanal Chem. 2020 Jul; 412(18):4211-4219. doi: 10.1007/s00216-020-02685-7. Epub 2020 May 11"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 23-11-2024