Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous Abstract"Experimental device for dioxin vapour generation: a steady and adjustable source of gaseous 2,3-DCDD"    Next Abstract"New sex attractants for 35 tortricid and 4 other lepidopterous species, found by systematic field screening in the Netherlands" »

J Chromatogr A


Title:Non-aqueous capillary electrophoresis for the analysis of acidic compounds using negative electrospray ionization mass spectrometry
Author(s):Bonvin G; Schappler J; Rudaz S;
Address:"School of Pharmaceutical Sciences, University of Geneva, University of Lausanne, Bd d'Yvoy 20, 1211 Geneva 4, Switzerland. School of Pharmaceutical Sciences, University of Geneva, University of Lausanne, Bd d'Yvoy 20, 1211 Geneva 4, Switzerland. Electronic address: serge.rudaz@unige.ch"
Journal Title:J Chromatogr A
Year:2014
Volume:20131113
Issue:
Page Number:163 - 173
DOI: 10.1016/j.chroma.2013.11.011
ISSN/ISBN:1873-3778 (Electronic) 0021-9673 (Linking)
Abstract:"Non-aqueous capillary electrophoresis (NACE) is an attractive CE mode, in which water solvent of the background electrolyte (BGE) is replaced by organic solvent or by a mixture of organic solvents. This substitution alters several parameters, such as the pKa, permittivity, viscosity, zeta potential, and conductivity, resulting in a modification of CE separation performance (i.e., selectivity and/or efficiency). In addition, the use of NACE is particularly well adapted to ESI-MS due to the high volatility of solvents and the low currents that are generated. Organic solvents reduce the number of side electrochemical reactions at the ESI tip, thereby allowing the stabilization of the ESI current and a decrease in background noise. All these features make NACE an interesting alternative to the aqueous capillary zone electrophoresis (CZE) mode, especially in combination with mass spectrometry (MS) detection. The aim of this work was to evaluate the use of NACE coupled to negative ESI-MS for the analysis of acidic compounds with two available CE-MS interfaces (sheath liquid and sheathless). First, NACE was compared to aqueous CZE for the analysis of several pharmaceutical acidic compounds (non-steroidal anti-inflammatory drugs, NSAIDs). Then, the separation performance and the sensitivity achieved by both interfaces were evaluated, as were the impact of the BGE and the sample composition. Finally, analyses of glucuronides in urine samples subjected to a minimal sample pre-treatment ('dilute-and-shoot') were performed by NACE-ESI-MS, and the matrix effect was evaluated. A 20- to 100-fold improvement in sensitivity was achieved using the NACE mode in combination with the sheathless interface and no matrix effect was observed regardless of the interfaces"
Keywords:"Electrolytes Electrophoresis, Capillary/*methods Glucuronides/isolation & purification/urine Humans Hydrogen-Ion Concentration Solvents/chemistry *Spectrometry, Mass, Electrospray Ionization Water Ce-ms Capillary electrophoresis Nace Negative ESI Sheath l;"
Notes:"MedlineBonvin, Gregoire Schappler, Julie Rudaz, Serge eng Netherlands 2013/12/10 J Chromatogr A. 2014 Jan 3; 1323:163-73. doi: 10.1016/j.chroma.2013.11.011. Epub 2013 Nov 13"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 19-12-2024