Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous Abstract"Characterization of urban aerosol: seasonal variation of mutagenicity and genotoxicity of PM(2.5), PM(1) and semi-volatile organic compounds"    Next AbstractIdentification of isoamyl acetate as an active component in the sting pheromone of the honey bee »

Rapid Commun Mass Spectrom


Title:Membrane inlet mass spectrometry of volatile organohalogen compounds in drinking water
Author(s):Bocchini P; Pozzi R; Andalo C; Galletti GC;
Address:"Dipartimento di Chimica 'G. Ciamician', Universita degli Studi di Bologna, via F. Selmi 2, 40126 Bologna, Italy. bocchini@ciam.unibo.it"
Journal Title:Rapid Commun Mass Spectrom
Year:1999
Volume:13
Issue:20
Page Number:2049 - 2053
DOI: 10.1002/(SICI)1097-0231(19991030)13:20<2049::AID-RCM752>3.0.CO;2-B
ISSN/ISBN:0951-4198 (Print) 0951-4198 (Linking)
Abstract:"The analysis of organic pollutants in drinking water is a topic of wide interest, reflecting on public health and life quality. Many different methodologies have been developed and are currently employed in this context, but they often require a time-consuming sample pre-treatment. This step affects the recovery of the highly volatile compounds. Trace analysis of volatile organic pollutants in water can be performed 'on-line' by membrane inlet mass spectrometry (MIMS). In MIMS, the sample is separated from the vacuum of the mass spectrometer by a thin polymeric hollow-fibre membrane. Gases and organic volatile compounds diffuse and concentrate from the sample into the hollow-fibre membrane, and from there into the mass spectrometer. The main advantages of the technique are that no pre-treatment of samples before analysis is needed and that it has fast response times and on-line monitoring capabilities. This paper reports the set-up of the analytical conditions for the analysis of volatile organohalogen compounds (chloroform, bromoform, bromodichloromethane, chlorodibromomethane, tetrachloroethylene, trichloroethylene, 1,1,1-trichloroethane, and carbon tetrachloride). Linearity of response, repeatability, detection limits, and spectra quality are evaluated"
Keywords:"Carbon Tetrachloride/analysis Chloroform/analysis Hydrocarbons, Brominated/analysis Hydrocarbons, Halogenated/*analysis Mass Spectrometry/*methods Quality Control Reproducibility of Results Tetrachloroethylene/analysis Trichloroethanes/analysis Trichloroe;"
Notes:"MedlineBocchini, P Pozzi, R Andalo, C Galletti, G C eng Research Support, Non-U.S. Gov't England 1999/10/08 Rapid Commun Mass Spectrom. 1999; 13(20):2049-53. doi: 10.1002/(SICI)1097-0231(19991030)13:20<2049::AID-RCM752>3.0.CO; 2-B"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 25-12-2024