Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractExposure to pheromones increases plasma corticosterone concentrations in a terrestrial salamander    Next AbstractMicrobial volatile organic compounds in moldy interiors: a long-term climate chamber study »

J Chromatogr Sci


Title:A full evaporation headspace technique with capillary GC and ITD: a means for quantitating volatile organic compounds in biological samples
Author(s):Schuberth J;
Address:"Department of Forensic Chemistry, University Hospital, Linkoping, Sweden"
Journal Title:J Chromatogr Sci
Year:1996
Volume:34
Issue:7
Page Number:314 - 319
DOI: 10.1093/chromsci/34.7.314
ISSN/ISBN:0021-9665 (Print) 0021-9665 (Linking)
Abstract:"The full evaporation technique (FET), which is a variant of headspace analysis used to overcome matrix effects, was combined with capillary gas chromatography (GC) and ion-trap detection (ITD). The aim was to enable quantitative tests of volatile organic compounds (VOCs) in blood and postmortem tissue samples. FET was applied to sample sized less than 35 mg whose VOCs were released from the matrix at an equilibration temperature of 130 degrees C. A capillary column with a nonpolar stationary phase was used for GC, and ITD was performed with the mass spectrometer run in full-scan mode. The potential of FET-GC-ITD was studied for the analysis of blood samples spiked with low concentrations of ethanol, acetone, 2-propanol, and 2-butanone and on brain tissue that contained methyl tert-butyl ether (MTBE), Benzene, toluene, ethylbenzene, o-, m-, and p-xylene, and propylbenzene. Samples were obtained from the bodies of victims who had inhaled smoke during an arson or accidental fire. There was a linear relationship between peak area and sample size, which indicates that the conditions of full evaporation were met and that the matrix effect was negated. The total analyte amount in the test sample at the limit of quantitation was in the range of 0.4-1 nmol for polar VOCs in blood and 0.03-0.1 nmol for nonpolar VOCs in brain tissue. Data on precision and accuracy of the method are reported"
Keywords:"Alcohols/*analysis/blood Benzene Derivatives/*analysis/blood *Brain Chemistry Chromatography, Gas/*methods/statistics & numerical data Fires Firesetting Behavior *Forensic Medicine Humans Ketones/*analysis/blood Sensitivity and Specificity Smoke/analysis;"
Notes:"MedlineSchuberth, J eng 1996/07/01 J Chromatogr Sci. 1996 Jul; 34(7):314-9. doi: 10.1093/chromsci/34.7.314"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 19-12-2024