Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous Abstract"Histomorphology and Chemical Constituents of Interdigital Gland of Vembur Sheep, Ovis aries"    Next Abstract"Localization of alpha 2u-globulin in the acinar cells of preputial gland, and confirmation of its binding with farnesol, a putative pheromone, in field rat (Millardia meltada)" »

Bioprocess Biosyst Eng


Title:Biodegradation of gaseous toluene with mixed microbial consortium in a biofilter: steady state and transient operation
Author(s):Rajamanickam R; Baskaran D;
Address:"Biochemical Engineering Laboratory, Department of Chemical Engineering, Annamalai University, Chidambaram, 608002, India. lect_ravi@yahoo.com. Biochemical Engineering Laboratory, Department of Chemical Engineering, Annamalai University, Chidambaram, 608002, India"
Journal Title:Bioprocess Biosyst Eng
Year:2017
Volume:20170904
Issue:12
Page Number:1801 - 1812
DOI: 10.1007/s00449-017-1834-7
ISSN/ISBN:1615-7605 (Electronic) 1615-7591 (Linking)
Abstract:"Petroleum oil refineries are massive emitters of risky volatile organic compounds (VOCs). Among the VOCs, toluene is taken into account as a significant pollutant. In the present study, a compost biofilter is used to treat the toluene vapor. However, an elimination capacity and removal efficiency of the biofilter was investigated for a wide range of toluene concentrations (0.29-3.8 g m(-3)) and operated for 54 days effectively. Elimination capacity of 93 g m(-3) h(-1) was recorded as maximum value at a toluene inlet concentration of 114 g m(-3) h(-1). An elimination capacity was perpetually better at the lower section of the biofilter, and therefore, the value was around 40-60 g m(-3) h(-1). The high removal efficiency of 97% was obtained at inlet toluene load of 60.55 g m(-3) h(-1). Hence, the biofilm was quite sensitive to handling transient loading conditions. The pressure drop had no vital impact on the biofilter performance. An Ottengraf model was applied to all phase of biofilter operation in each of the diffusion limiting region and reaction limiting region. The parameters of the model K (1) (75.95 g(1/2) m(-3/2) h(-1)) and K (0) (90.51 g m(-3) h(-1)) were obtained from diffusion and reaction limiting region severally. However, K (1) was used to calculate the theoretical elimination capacities, and therefore, K (0) was used to discover the biofilm thickness. By the way, the average biofilm thickness was found to be 0.98 mm from reaction limiting region"
Keywords:"Filtration/*instrumentation Gases/*metabolism *Microbial Consortia Microscopy, Electron, Scanning Toluene/*metabolism Biofilm thickness Biofilter Elimination capacity Removal efficiency Toluene;"
Notes:"MedlineRajamanickam, Ravi Baskaran, Divya eng 43-329/2014/Research Grants Council, University Grants Committee/ Germany 2017/09/06 Bioprocess Biosyst Eng. 2017 Dec; 40(12):1801-1812. doi: 10.1007/s00449-017-1834-7. Epub 2017 Sep 4"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 19-12-2024