Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractModelling of micropollutant removal in biological wastewater treatments: a review    Next AbstractChemotaxis of Allomyces gametes »

Indoor Air


Title:Class separation of buildings with high and low prevalence of SBS by principal component analysis
Author(s):Pommer L; Fick J; Sundell J; Nilsson C; Sjostrom M; Stenberg B; Andersson B;
Address:"Department of Chemistry, Environmental Chemistry, Umea University, Umea, Sweden"
Journal Title:Indoor Air
Year:2004
Volume:14
Issue:1
Page Number:16 - 23
DOI: 10.1111/j.1600-0668.2004.00203.x
ISSN/ISBN:0905-6947 (Print) 0905-6947 (Linking)
Abstract:"In this study, we were able to separate buildings with high and low prevalence of sick building syndrome (SBS) using principal component analysis. The prevalence of SBS was defined by the presence of at least one typical skin, mucosal and general (headache and fatigue) symptom. Data from the Swedish Office Illness Study describing the presence and level of chemical compounds in outdoor, supply, and room air, respectively, were evaluated together with information about the buildings in six models. When all data were included the most complex model was able to separate 71% of the high prevalence buildings from the low prevalence buildings. The most important variable that separates the high prevalence buildings from the low prevalence buildings was a more frequent occurrence or a higher concentration of compounds with shorter retention time in the high prevalence buildings. Elevated relative humidity in supply and room air and higher levels of total volatile organic compounds in outdoor and supply air were more common in high prevalence buildings. Ten building variables also contributed to the separation of the two classes of low and high prevalence buildings"
Keywords:"Air Pollutants/adverse effects/*analysis Air Pollution, Indoor/adverse effects/prevention & control Environmental Monitoring/*methods Epidemiological Monitoring Humans Prevalence Severity of Illness Index Sick Building Syndrome/*classification/*epidemiolo;"
Notes:"MedlinePommer, L Fick, J Sundell, J Nilsson, C Sjostrom, M Stenberg, B Andersson, B eng Research Support, Non-U.S. Gov't England 2004/02/06 Indoor Air. 2004 Feb; 14(1):16-23. doi: 10.1111/j.1600-0668.2004.00203.x"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 21-11-2024