« Previous AbstractComparative analysis of formaldehyde and toluene sorption on indoor floorings and consequence on Indoor Air Quality    Next AbstractHow to put all your eggs in one basket: empirical patterns of offspring provisioning throughout a mother's lifetime »

Anal Chim Acta


Title:Assessment of gas-phase concentrations of organophosphate flame retardants at the material surface using a midget emission cell coupled to solid-phase microextraction
Author(s):Plaisance H; Ghislain M; Desauziers V;
Address:"IPREM, IMT Mines Ales, Universite de Pau et des Pays de L'Adour, E2S UPPA, CNRS, Pau, France. Electronic address: herve.plaisance@mines-ales.fr. IPREM, IMT Mines Ales, Universite de Pau et des Pays de L'Adour, E2S UPPA, CNRS, Pau, France"
Journal Title:Anal Chim Acta
Year:2021
Volume:20210923
Issue:
Page Number:339100 -
DOI: 10.1016/j.aca.2021.339100
ISSN/ISBN:1873-4324 (Electronic) 0003-2670 (Linking)
Abstract:"Actual methods for on-site measurement of gaseous concentrations of Semi-Volatile Organic Compounds (SVOCs) at the material surface (y(0)) are not yet sufficiently developed mainly due to sampling difficulties. These concentrations are the key data to improve knowledge about indoor sources and human exposure to SVOCs. To the end, a specific emission cell coupled to solid-phase microextraction (SPME) was developed. The main challenge with this method is calibration because of very low volatility of SVOCs and static sampling mode. In this study, a generating system of organophosphate flame retardants (OFRs) using polyurethane foam as source combined with an active sampling method with Tenax tubes was proposed as a novel calibration device for SPME-based method. The generating system delivered stable OFR concentrations after 190 h of operation with a variation not exceeding +/-5%. It allowed to obtain robust calibrations for tris-(2-chloropropyl)-phosphate (TCPP) and tri-butyl-phosphate (TBP) measured with the emission cell coupled to SPME-based method, define the optimal sampling requirements and achieve reproducible and accurate measurements of y(0) at mug.m(-3) level. TCPP and TBP gas-phase concentrations at the polyurethane foam surface (y(0)) were followed up over more 228 days under controlled temperature conditions. A high stability of these concentrations was observed showing that polyurethane foam acts as a stable and continuous source of organophosphate flame retardants indoors. This novel method should be useful for assessing the dynamic of emissions from indoor sources and potential exposure to SVOCs in indoor environments"
Keywords:"*Air Pollution, Indoor/analysis Environmental Monitoring *Flame Retardants/analysis Gases Humans Organophosphates/analysis Solid Phase Microextraction *Volatile Organic Compounds/analysis Gas-phase SVOCs generation System Indoor air quality Material emiss;"
Notes:"MedlinePlaisance, Herve Ghislain, Mylene Desauziers, Valerie eng Netherlands 2021/11/11 Anal Chim Acta. 2021 Nov 22; 1186:339100. doi: 10.1016/j.aca.2021.339100. Epub 2021 Sep 23"

 