Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractMale-induced puberty acceleration in young female wild mice: hormonal regulation and source of pheromonal cue    Next AbstractDetermination of hazardous VOCs and nicotine released from mainstream smoke by the combination of the SPME and GC-MS methods »

J Chromatogr A


Title:Comparative analysis of odorous volatile organic compounds between direct injection and solid-phase microextraction: development and validation of a gas chromatography-mass spectrometry-based methodology
Author(s):Pandey SK; Kim KH;
Address:"Atmospheric Environment Laboratory, Department of Earth and Environmental Sciences, Sejong University, 98 Goon Ja Dong, Gwang Jin Goo, Seoul 143-747, South Korea"
Journal Title:J Chromatogr A
Year:2009
Volume:20090518
Issue:28
Page Number:5436 - 5444
DOI: 10.1016/j.chroma.2009.05.022
ISSN/ISBN:1873-3778 (Electronic) 0021-9673 (Linking)
Abstract:"In this study, the feasibility of GC-MS was evaluated for the quantification of odorous volatile organic compounds (VOCs) in environmental samples. These included methyl ethyl ketone, isobutyl alcohol, methyl isobutyl ketone, and butyl acetate plus benzene, toluene, and xylene (BTX). For this purpose, the gaseous standard for these VOCs were analyzed by GC-MS with the aid of both direct injection (DI) into the GC injector and solid-phase microextraction (SPME). The liquid phase standard prepared independently was tested additionally by the DI method as a reference to gaseous calibration. The detection limit (DL) values, when tested for basic quality assurance in this study, showed large differences between DI (0.002-0.007 ng) and SPME method (1.03-1.81 ng) in terms of absolute mass. The DL values, when expressed in terms of concentration (v/v), showed considerable improvement in SPME (below 0.40 nmol mol(-1)) relative to the DI method (approximately 6-15 nmol mol(-1)). The reliability of the GC-MS method was further validated through an analysis of real environmental samples collected from an industrial area"
Keywords:Air/analysis Air Pollutants/analysis Calibration Gas Chromatography-Mass Spectrometry/*methods Linear Models Odorants/*analysis Reproducibility of Results Sensitivity and Specificity Solid Phase Microextraction/*methods Volatile Organic Compounds/*analysi;
Notes:"MedlinePandey, Sudhir Kumar Kim, Ki-Hyun eng Comparative Study Research Support, Non-U.S. Gov't Netherlands 2009/06/06 J Chromatogr A. 2009 Jul 10; 1216(28):5436-44. doi: 10.1016/j.chroma.2009.05.022. Epub 2009 May 18"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 19-12-2024