Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractIntensive cattle grazing affects pasture litter-fall: an unrecognized nitrous oxide source    Next Abstract3D Printing of Metal-Organic Framework-Based Ionogels: Wearable Sensors with Colorimetric and Mechanical Responses »

J Sep Sci


Title:The effect of cold trap adsorbents on the gas chromatographic analysis of ambient VOCs under Peltier cooling conditions
Author(s):Pal R; Kim KH;
Address:"Atmospheric Environment Laboratory, Department of Earth and Environmental Sciences, Sejong University, Seoul, Korea"
Journal Title:J Sep Sci
Year:2008
Volume:31
Issue:6-Jul
Page Number:1100 - 1109
DOI: 10.1002/jssc.200700531
ISSN/ISBN:1615-9314 (Electronic) 1615-9306 (Linking)
Abstract:"In this work, the relative analytical performance of the GC-based detection method was investigated with a major focus on cold trap (CT) adsorbent materials against four aromatic volatile organic compounds (VOCs) (e. g., benzene, toluene, xylene, and styrene). A series of calibration experiments were hence conducted under cryofocusing conditions formed by the Peltier cooling system in a thermal desorber (TD) unit. During the course of this study, comparative calibration datasets were acquired for each of the three CT types: (i) CT (I) = Carbopack B + Carbopack C, (ii) CT (II) = Carbopack B + Carboxen 1000, and (iii) CT (III) = Tenax TA. All calibration datasets were obtained under subambient temperature (-10 degrees C) conditions controlled by the Peltier cooling system. The reliability of the calibration data was also assessed in an ancillary experiment with the aid of the modified injection through a thermal desorber (MITD) method. The results demonstrated that the GC detection properties of different VOCs were not altered significantly between different CT applications under Peltier conditions, although relative sensitivity could be distinguished moderately depending on the CT type"
Keywords:"Adsorption Calibration Chromatography, Gas/*methods *Cold Temperature Molecular Structure Organic Chemicals/*analysis/*chemistry Volatilization;"
Notes:"MedlinePal, Raktim Kim, Ki-Hyun eng Research Support, Non-U.S. Gov't Germany 2008/03/11 J Sep Sci. 2008 Apr; 31(6-7):1100-9. doi: 10.1002/jssc.200700531"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 22-11-2024