Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractImpact of organic matter on transformation during thermal remediation of pyrene-contaminated substrates    Next AbstractEvaluation of spoilage potential and volatile metabolites production by Shewanella baltica isolated from modified atmosphere packaged live mussels »

Chemosphere


Title:Application of polyoxymethylene passive air sampler to monitor hydrophobic organics in air around a confined disposal facility
Author(s):Odetayo AA; Reible DD; Acevedo-Mackey D; Price C; Thai L;
Address:"Department of Civil, Environmental and Construction Engineering, Texas Tech University, 911 Boston Avenue, Lubbock, TX, 79409, USA. Department of Civil, Environmental and Construction Engineering, Texas Tech University, 911 Boston Avenue, Lubbock, TX, 79409, USA. Electronic address: danny.reible@ttu.edu. U. S Army Engineer Research and Development Center, 3909 Halls Ferry Rd. Vicksburg, Mississippi, 39180, USA. U. S Army Corps of Engineers, Chicago District, USA"
Journal Title:Chemosphere
Year:2021
Volume:20200815
Issue:
Page Number:127827 -
DOI: 10.1016/j.chemosphere.2020.127827
ISSN/ISBN:1879-1298 (Electronic) 0045-6535 (Linking)
Abstract:"Volatile losses of hydrophobic organic contaminants from a confined disposal facility (CDF) containing dredged contaminated sediments is of substantial concern to surrounding communities. A partitioning passive sampling approach using polyoxymethylene (POM) was applied to measure long-term average (weeks to months) air concentrations resulting from evaporation at a CDF. Measurements at 10 locations surrounding the CDF using the POM air samplers indicated that the highest concentrations of SigmaPCBs approximately 13 ng/m(3) and SigmaPAHs approximately 65 ng/m(3) were measured during an active dredge material placement period when the average temperature was 23 degrees C. The measurements were dominated by the more volatile, lower molecular weight compounds of each type. Partitioning to the POM during the post dredge material placement period with average temperature of 5 degrees C was corrected for temperature and the measured summation operatorPCBs and summation operatorPAHs were approximately 3 ng/m(3) and 45 ng/m(3) respectively. The partitioning passive sampling measurements agreed well with the available weekly 24-h high-volume air samples (HVAS) averaged over the POM equilibration time for lower congener number PCBs (15, 18, 20/28 and 31) and naphthalene but were as much as 10 times lower than HVAS for high molecular weight PAHs. The difference was likely the result of the greater association of these PAHs with particulates and sources other than evaporation from the CDF. The POM air sampler achieved the goal of providing a long-term average air concentration without having to collect, analyze and average multiple HVAS samples although the technique is largely limited to the lower molecular weight PAHs and PCBs and different equilibration times for different compounds complicate its use and analysis"
Keywords:"*Air Pollutants/analysis Environmental Monitoring *Polychlorinated Biphenyls/analysis *Polycyclic Aromatic Hydrocarbons/analysis Resins, Synthetic Air concentration Confined disposal facility PAHs PCBs POM air Sampler Passive air sampling;"
Notes:"MedlineOdetayo, Adesewa A Reible, Danny D Acevedo-Mackey, Damarys Price, Cynthia Thai, Le eng England 2020/08/25 Chemosphere. 2021 Jan; 263:127827. doi: 10.1016/j.chemosphere.2020.127827. Epub 2020 Aug 15"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 18-06-2024