Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractDynamic changes to signal allocation rules in response to variable social environments in house mice    Next AbstractDiffusive uptake rates for passive air sampling: Application to volatile organic compound exposure during FIREX-AQ campaign »

Toxicol Ind Health


Title:Exacerbation of chemical sensitivity: a case study
Author(s):Miller CS; Gammage RB; Jankovic JT;
Address:"Department of Family Practice, University of Texas Health Science Center at San Antonio 78284-7794, USA. millercs@uthscsa.edu"
Journal Title:Toxicol Ind Health
Year:1999
Volume:15
Issue:3-Apr
Page Number:398 - 402
DOI: 10.1177/074823379901500313
ISSN/ISBN:0748-2337 (Print) 0748-2337 (Linking)
Abstract:"We report exacerbation of symptoms and chemical intolerances in three of four self-described chemically sensitive women following relocation to a newly constructed office building. Levels of total volatile organic compounds (TVOCs) in this building prior to occupancy were approximately 200 micrograms/m3 (toluene equivalent units) with a myriad of individual components present. By day 50 after occupancy, the concentration of TVOCs in the building dropped to approximately 50 micrograms/m3. Nevertheless, three women reported significant worsening of their symptoms with spreading of their sensitivities to previously tolerated chemical exposures. One woman relocated to another building, while the other two managed their symptoms by reducing time spent in the building or by using a room air cleaner. By day 600 following occupancy, although TVOCs had increased significantly (perhaps due to cleaning agents), there were fewer individual VOCs present in the air, and some of the women were able to tolerate the air in the building. We conclude that complex mixtures of VOCs at very low levels tolerated by the majority of building occupants may pose problems for persons who report pre-existing chemical sensitivities. TVOC measurements may not correlate with symptoms in these individuals. Reasonable accommodations by an employer can reduce problem exposures, making it possible for some affected individuals to continue productive employment"
Keywords:"Air Pollution, Indoor/*adverse effects Female Humans Hypersensitivity/*etiology In Vitro Techniques Multiple Chemical Sensitivity/*etiology Organic Chemicals/*analysis/*toxicity Perceptual Masking/physiology Quality of Life/*psychology Surveys and Questio;"
Notes:"MedlineMiller, C S Gammage, R B Jankovic, J T eng England 1999/07/23 Toxicol Ind Health. 1999 Apr-Jun; 15(3-4):398-402. doi: 10.1177/074823379901500313"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 16-11-2024