Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractMultiphasic on/off pheromone signalling in moths as neural correlates of a search strategy    Next AbstractActivation of TRPA1 by volatile organic chemicals leading to sensory irritation »

J Chromatogr A


Title:Multicomponent analysis of volatile organic compounds in water by automated purge and trap coupled to gas chromatography-mass spectrometry
Author(s):Martinez E; Lacorte S; Llobet I; Viana P; Barcelo D;
Address:"Department of Environmental Chemistry, IIQAB-CSIC, Barcelona, Spain"
Journal Title:J Chromatogr A
Year:2002
Volume:959
Issue:1-Feb
Page Number:181 - 190
DOI: 10.1016/s0021-9673(02)00439-9
ISSN/ISBN:0021-9673 (Print) 0021-9673 (Linking)
Abstract:"The performance of an automated purge and trap concentrator coupled to gas chromatography-mass spectrometric detection was evaluated by analyzing 40 volatile organic compounds of different chemical families. Compounds chosen defined as toxic for the environment and for human health were selected according to Directive 76/464/CEE. The present work includes: (i) the optimization of the purge and trap conditions, (ii) the establishment of quality parameters and in last instance (iii) the analysis of surface waters. The analytical method consisted of a modification of the EPA Method 524.2 in which water was pumped, via an automated AquaTek 70 Liquid Autosampler to a 25-ml purging device, where samples were purged and trapped in a Tenax or Tenax-Silica and Charcoal column. Afterwards, helium was used to desorb the trapped analytes that flow directly into the GC column. Mass spectrometric analysis was carried out in selected ion monitoring and scan modes to ensure quantification and confirmation of the results. Parameters optimized were the sample volume analyzed, bubbling flow-rate and time and temperature of desorption. Optimal conditions lead to mean recoveries of 80%, limits of detection between 0.002 and 0.1 microg/l, linearity from 0.01 to 2.5 microg/l and maximum standard deviation of 10%, using a Tenax trap. This protocol permitted a high precision and sample throughput and was used to determine volatile organic compounds in surface river, effluents and coastal waters of Portugal, on a routine basis"
Keywords:Calibration Environmental Monitoring/methods Gas Chromatography-Mass Spectrometry/*methods Organic Chemicals/*analysis Volatilization Water/*chemistry;
Notes:"MedlineMartinez, Elena Lacorte, Silvia Llobet, Isabel Viana, Paula Barcelo, Damia eng Research Support, Non-U.S. Gov't Netherlands 2002/07/27 J Chromatogr A. 2002 Jun 14; 959(1-2):181-90. doi: 10.1016/s0021-9673(02)00439-9"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 19-12-2024