Title: | Multi-dimensional gas chromatography with a planar microfluidic device for the characterization of volatile oxygenated organic compounds |
Author(s): | Luong J; Gras R; Cortes H; Shellie RA; |
Address: | "Australian Centre for Research on Separation Science (ACROSS), University of Tasmania, Private Bag 75, Hobart, Tasmania 7001, Australia" |
DOI: | 10.1016/j.chroma.2012.01.073 |
ISSN/ISBN: | 1873-3778 (Electronic) 0021-9673 (Linking) |
Abstract: | "Oxygenated compounds like methanol, ethanol, 1-propanol, 2-propanol, 1-butanol, acetaldehyde, crotonaldehyde, ethylene oxide, tetrahydrofuran, 1,4-dioxane, 1,3-dioxolane, and 2-chloromethyl-1,3-dioxolane are commonly encountered in industrial manufacturing processes. Despite the availability of a variety of column stationary phases for chromatographic separation, it is difficult to separate these solutes from their respective matrices using single dimension gas chromatography. Implemented with a planar microfluidic device, conventional two-dimensional gas chromatography and the employment of chromatographic columns using dissimilar separation mechanisms like that of a selective wall-coated open tubular column and an ionic sorbent column have been successfully applied to resolve twelve industrially significant volatile oxygenated compounds in both gas and aqueous matrices. A Large Volume Gas Injection System (LVGIS) was also employed for sample introduction to enhance system automation and precision. By successfully integrating these concepts, in addition to having the capability to separate all twelve components in one single analysis, features associated with multi-dimensional gas chromatography like dual retention time capability, and the ability to quarantine undesired chromatographic contaminants or matrix components in the first dimension column to enhance overall system cleanliness were realized. With this technique, a complete separation for all the compounds mentioned can be carried out in less than 15 min. The compounds cited can be analyzed over a range of 250 ppm (v/v) to 100 ppm (v/v) with a relative standard deviation of less than 5% (n=20) with high degree of reliability" |
Keywords: | "Chromatography, Gas/instrumentation/*methods Microfluidic Analytical Techniques/*instrumentation Oxidation-Reduction Oxygen/chemistry Reproducibility of Results Volatile Organic Compounds/*analysis;" |
Notes: | "MedlineLuong, J Gras, R Cortes, H Shellie, R A eng Research Support, Non-U.S. Gov't Netherlands 2012/03/14 J Chromatogr A. 2012 Sep 14; 1255:216-20. doi: 10.1016/j.chroma.2012.01.073. Epub 2012 Feb 25" |