Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractMoth pheromone-selective projection neurons with cell bodies in the antennal lobe lateral cluster exhibit diverse morphological and neurophysiological characteristics    Next AbstractEfficacy of Retrievable Inferior Vena Cava Filter Placement in the Prevention of Pulmonary Embolism during Catheter-Directed Thrombectomy for Proximal Lower-Extremity Deep Vein Thrombosis »

J Hazard Mater


Title:The effect of nitrate on ethylene biofiltration
Author(s):Lee SH; Li C; Heber AJ;
Address:"Department of Agricultural and Biological Engineering, Purdue University, 225 South University St., West Lafayette, 47907-2093 IN, USA. lee323@alumni.purdue.edu"
Journal Title:J Hazard Mater
Year:2012
Volume:20120928
Issue:
Page Number:331 - 339
DOI: 10.1016/j.jhazmat.2012.09.051
ISSN/ISBN:1873-3336 (Electronic) 0304-3894 (Linking)
Abstract:"This study investigated the effects of filter media types and nitrate (NO(3)(-)) concentrations in nutrient solutions on C(2)H(4) biofiltration. A new nutrient solution with zero NO(3)(-) concentration was supplied to two perlite-bed biotrickling filters, two perlite-bed biofilters, and two GAC (Granular Activated Carbon)-bed biofilters, while the other with 2 g L(-1) of NO(3)(-) was used for the other two GAC biofilters. All reactors underwent a total test duration of over 175 days with an EBRT (Empty Bed Residence Time) of 30 s, inlet gas flow rate of 7 L min(-1), and inlet C(2)H(4) concentrations of 20-30 mg m(-3). NO(3)(-) concentration and media type significantly affected the C(2)H(4) removal efficiencies in all types of biofiltration. The perlite media with no NO(3)(-) achieved C(2)H(4) removal efficiencies 10-50% higher than the others. A NO(3)(-) concentration as high as 2 g L(-1) in the original nutrient solution may act as an inhibitor that suppresses the growth or activity of C(2)H(4) degraders. In addition, the perlite media resulted in higher C(2)H(4) removal efficiencies than GAC media, because the hydrophilic surface of the perlite leads to a higher moisture content and thus to favorable microbial growth"
Keywords:"Air Pollutants/*isolation & purification Biodegradation, Environmental Biofilms/growth & development Bioreactors/*microbiology Equipment Design Ethylenes/*isolation & purification Filtration/instrumentation/*methods Hydrogen-Ion Concentration Nitrates/*ch;"
Notes:"MedlineLee, Sang-Hun Li, Congna Heber, Albert J eng Research Support, Non-U.S. Gov't Netherlands 2012/10/16 J Hazard Mater. 2012 Nov 30; 241-242:331-9. doi: 10.1016/j.jhazmat.2012.09.051. Epub 2012 Sep 28"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 25-11-2024