Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractAir sampling and analysis of volatile organic compounds with solid phase microextraction    Next AbstractMethod for sampling and analysis of volatile biomarkers in process gas from aerobic digestion of poultry carcasses using time-weighted average SPME and GC-MS »

J Air Waste Manag Assoc


Title:"Evaluation of sample recovery of malodorous livestock gases from air sampling bags, solid-phase microextraction fibers, Tenax TA sorbent tubes, and sampling canisters"
Author(s):Koziel JA; Spinhirne JP; Lloyd JD; Parker DB; Wright DW; Kuhrt FW;
Address:"Texas Agricultural Experiment Station, Texas A&M University, Amarillo, TX, USA. koziel@iastate.edu"
Journal Title:J Air Waste Manag Assoc
Year:2005
Volume:55
Issue:8
Page Number:1147 - 1157
DOI: 10.1080/10473289.2005.10464711
ISSN/ISBN:1096-2247 (Print) 1096-2247 (Linking)
Abstract:"Odorous gases associated with livestock operations are complex mixtures of hundreds if not thousands of compounds. Research is needed to know how best to sample and analyze these compounds. The main objective of this research was to compare recoveries of a standard gas mixture of 11 odorous compounds from the Carboxen/PDMS 75-microm solid-phase microextraction fibers, polyvinyl fluoride (PVF; Tedlar), fluorinated ethylene propylene copolymer (FEP; Teflon), foil, and polyethylene terephthalate (PET; Melinex) air sampling bags, sorbent 2,b-diphenylene-oxide polymer resin (Tenax TA) tubes, and standard 6-L Stabilizer sampling canisters after sample storage for 0.5, 24, and 120 (for sorbent tubes only) hrs at room temperature. The standard gas mixture consisted of 7 volatile fatty acids (VFAs) from acetic to hexanoic, and 4 semivolatile organic compounds including p-cresol, indole, 4-ethylphenol, and 2'-aminoacetophenone with concentrations ranging from 5.1 ppb for indole to 1270 ppb for acetic acid. On average, SPME had the highest mean recovery for all 11 gases of 106.2%, and 98.3% for 0.5- and 24-hr sample storage time, respectively. This was followed by the Tenax TA sorbent tubes (94.8% and 88.3%) for 24 and 120 hr, respectively; PET bags (71.7% and 47.2%), FEP bags (75.4% and 39.4%), commercial Tedlar bags (67.6% and 22.7%), in-house-made Tedlar bags (47.3% and 37.4%), foil bags (16.4% and 4.3%), and canisters (4.2% and 0.5%), for 0.5 and 24 hr, respectively. VFAs had higher recoveries than semivolatile organic compounds for all of the bags and canisters. New FEP bags and new foil bags had the lowest and the highest amounts of chemical impurities, respectively. New commercial Tedlar bags had measurable concentrations of N,N-dimethyl acetamide and phenol. Foil bags had measurable concentrations of acetic, propionic, butyric, valeric, and hexanoic acids"
Keywords:"Acetophenones/analysis Adsorption Air Pollutants/*analysis Aluminum Animals *Animals, Domestic Cresols/analysis Environmental Monitoring/*instrumentation/methods Fatty Acids, Volatile/analysis Gas Chromatography-Mass Spectrometry Gases/analysis Indoles/an;"
Notes:"MedlineKoziel, Jacek A Spinhirne, Jarett P Lloyd, Jenny D Parker, David B Wright, Donald W Kuhrt, Fred W eng Comparative Study 2005/09/29 J Air Waste Manag Assoc. 2005 Aug; 55(8):1147-57. doi: 10.1080/10473289.2005.10464711"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 25-11-2024