Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractBacteriocin production augments niche competition by enterococci in the mammalian gastrointestinal tract    Next Abstract"Development of an in vitro batch-type closed gas exposure device with an alveolar epithelial cell line, A549, for toxicity evaluations of gaseous compounds" »

Rev Sci Instrum


Title:Enabling liquid vapor analysis using synchrotron VUV single photon ionization mass spectrometry with a microfluidic interface
Author(s):Komorek R; Xu B; Yao J; Ablikim U; Troy TP; Kostko O; Ahmed M; Yu XY;
Address:"Atmospheric Sciences and Global Change Division, PNNL, Richland, Washington 99354, USA. Chemical Sciences Division, Lawrence Berkeley National Laboratory, Berkeley, California 94720, USA"
Journal Title:Rev Sci Instrum
Year:2018
Volume:89
Issue:11
Page Number:115105 -
DOI: 10.1063/1.5048315
ISSN/ISBN:1089-7623 (Electronic) 0034-6748 (Linking)
Abstract:"Vacuum ultraviolet (VUV) single photon ionization mass spectrometry (SPI-MS) is a vacuum-based technique typically used for the analysis of gas phase and solid samples, but not for liquids due to the challenge in introducing volatile liquids in a vacuum. Here we present the first demonstration of in situ liquid analysis by integrating the System for Analysis at the Liquid Vacuum Interface (SALVI) microfluidic reactor into VUV SPI-MS. Four representative volatile organic compound (VOC) solutions were used to illustrate the feasibility of liquid analysis. Our results show the accurate mass identification of the VOC molecules and the reliable determination of appearance energy that is consistent with ionization energy for gaseous species in the literature as reported. This work validates that the vacuum-compatible SALVI microfluidic interface can be utilized at the synchrotron beamline and enable the in situ study of gas-phase molecules evaporating off the surface of a liquid, which holds importance in the study of condensed matter chemistry"
Keywords:
Notes:"PubMed-not-MEDLINEKomorek, R Xu, B Yao, J Ablikim, U Troy, T P Kostko, O Ahmed, M Yu, X Y eng 2018/12/07 Rev Sci Instrum. 2018 Nov; 89(11):115105. doi: 10.1063/1.5048315"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 25-12-2024