Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractEffects of hyperhomocysteinemia during the gestational period on ossification in rat embryo    Next AbstractEnvironmental impact of highway construction and repair materials on surface and ground waters. Case study: crumb rubber asphalt concrete »

Lipids


Title:Developing FT-NIR and PLS1 Methodology for Predicting Adulteration in Representative Varieties/Blends of Extra Virgin Olive Oils
Author(s):Azizian H; Mossoba MM; Fardin-Kia AR; Karunathilaka SR; Kramer JK;
Address:"NIR Technologies Inc., Oakville, ON, L6M 2M2, Canada. hazizian@nirtechnologies.com. Food and Drug Administration, Center for Food Safety and Applied Nutrition, Office of Regulatory Science, College Park, MD, USA. magdi.mossoba@fda.hhs.gov. Food and Drug Administration, Center for Food Safety and Applied Nutrition, Office of Regulatory Science, College Park, MD, USA. Guelph Food Research Center, Agriculture and Agri-Food Canada, Guelph, ON, Canada"
Journal Title:Lipids
Year:2016
Volume:20160927
Issue:11
Page Number:1309 - 1321
DOI: 10.1007/s11745-016-4195-0
ISSN/ISBN:1558-9307 (Electronic) 0024-4201 (Linking)
Abstract:"It was previously demonstrated that Fourier transform near infrared (FT-NIR) spectroscopy and partial least squares (PLS1) were successfully used to assess whether an olive oil was extra virgin, and if adulterated, with which type of vegetable oil and by how much using previously developed PLS1 calibration models. This last prediction required an initial set of four PLS1 calibration models that were based on gravimetrically prepared mixtures of a specific variety of extra virgin olive oil (EVOO) spiked with adulterants. The current study was undertaken after obtaining a range of EVOO varieties grown in different countries. It was found that all the different types of EVOO varieties investigated belonged to four distinct groups, and each required the development of additional sets of specific PLS1 calibration models to ensure that they can be used to predict low concentrations of vegetable oils high in linoleic, oleic, or palmitic acid, and/or refined olive oil. These four distinct sets of PLS1 calibration models were required to cover the range of EVOO varieties with a linoleic acid content from 1.3 to 15.5 % of total fatty acids. An FT-NIR library was established with 66 EVOO products obtained from California and Europe. The quality and/or purity of EVOO were assessed by determining the FT-NIR Index, a measure of the volatile content of EVOO. The use of these PLS1 calibration models made it possible to predict the authenticity of EVOO and the identity and quantity of potential adulterant oils in minutes"
Keywords:"Fatty Acids/*analysis Food Contamination/*analysis Least-Squares Analysis Olive Oil/*analysis Spectroscopy, Fourier Transform Infrared/*methods Volatile Organic Compounds/*analysis Extra virgin olive oil FA markers Ft-nir Pls Volatile compounds;"
Notes:"MedlineAzizian, Hormoz Mossoba, Magdi M Fardin-Kia, Ali Reza Karunathilaka, Sanjeewa R Kramer, John K G eng 2016/10/25 Lipids. 2016 Nov; 51(11):1309-1321. doi: 10.1007/s11745-016-4195-0. Epub 2016 Sep 27"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 22-11-2024